Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN 54-31:2014+A1:2016 Fire detection and fire alarm system Multi-sensor fire detectors. Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors
Sponsored link
sklademVydáno: 2016-05-31
BS EN 54-31:2014+A1:2016 Fire detection and fire alarm system Multi-sensor fire detectors. Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors

BS EN 54-31:2014+A1:2016

Fire detection and fire alarm system Multi-sensor fire detectors. Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
384.29 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
38.43 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
115.29 €
Anglicky Hardcopy
In stock
384.29 €
Označení normy:BS EN 54-31:2014+A1:2016
Počet stran:112
Vydáno:2016-05-31
ISBN:978 0 580 89585 2
Status:Standard
DESCRIPTION

BS EN 54-31:2014+A1:2016


This standard BS EN 54-31:2014+A1:2016 Fire detection and fire alarm system is classified in these ICS categories:
  • 13.220.20 Fire protection

This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection and fire alarm systems installed in and around buildings (see EN 54‑1:2011 ), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one carbon monoxide (CO) sensor and optionally one or more heat sensors, utilizing the combination of the detected phenomena. This European Standard covers only modes of operation, where at least the signals of both smoke and carbon monoxide sensors are continuously evaluated.

deleted text

Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors, which are having special characteristics suitable for the detection of specific fire risks are not covered by this European Standard. The performance requirements for any additional functions are beyond the scope of this standard (e.g. additional features or enhanced functionality for which this European Standard does not define a test or assessment method).