Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN 60404-15:2012+A1:2017 Magnetic materials Methods for the determination of the relative magnetic permeability of feebly magnetic materials
Sponsored link
sklademVydáno: 2017-03-31
BS EN 60404-15:2012+A1:2017 Magnetic materials Methods for the determination of the relative magnetic permeability of feebly magnetic materials

BS EN 60404-15:2012+A1:2017

Magnetic materials Methods for the determination of the relative magnetic permeability of feebly magnetic materials

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
254.56 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
25.46 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
76.37 €
Anglicky Hardcopy
In stock
254.56 €
Označení normy:BS EN 60404-15:2012+A1:2017
Počet stran:28
Vydáno:2017-03-31
ISBN:978 0 580 87088 0
Status:Standard
DESCRIPTION

BS EN 60404-15:2012+A1:2017


This standard BS EN 60404-15:2012+A1:2017 Magnetic materials is classified in these ICS categories:
  • 29.030 Magnetic materials
  • 17.220.01 Electricity. Magnetism. General aspects

This part of IEC 60404 specifies a solenoid method, a magnetic moment method, a magnetic balance method and a permeability meter method for the determination of the relative magnetic permeability of feebly magnetic materials (including austenitic stainless steel). The magnetic balance and permeability meter methods are both comparison methods calibrated using reference materials to determine the value of the relative magnetic permeability of the test specimen. The relative magnetic permeability range for each of these methods is shown in Table 1. The methods given are for applied magnetic field strengths of between 5 kA/m and 100 kA/m.

Table 1
Relative magnetic permeability ranges for the methods described
Measurement method Relative magnetic permeability range
Solenoid 1,003 to 2
Magnetic moment 1,003 to 1,2
Magnetic balance 1,003 to 5
Permeability meter 1,003 to 2
NOTE 1

The relative magnetic permeability range given for the magnetic balance method covers the inserts provided with a typical instrument. These can only be assessed at values for which calibrated reference materials exist.

NOTE 2

For a relative magnetic permeability larger than 2, a reference material cannot be calibrated using this written standard. A note of this is given in the test report explaining that the values measured using the magnetic balance are for indication only.

The solenoid method is the reference method. The magnetic moment method described is used mainly for the measurement of the relative magnetic permeability of mass standards.

Two comparator methods used by industry are described. These can be calibrated using reference materials for which the relative magnetic permeability has been determined using the reference method. When suitable, the magnetic moment method can also be used. The dimensions of the reference material need to be given careful consideration when determining the uncertainty in the calibration value due to self-demagnetization effects. See Annex A for more information on correcting for self-demagnetization.