Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN 60598-2-6:1995 Luminaires. Particular requirements Luminaires with built-in transformers for filament lamps
sklademVydáno: 1995-02-15
BS EN 60598-2-6:1995 Luminaires. Particular requirements Luminaires with built-in transformers for filament lamps

BS EN 60598-2-6:1995

Luminaires. Particular requirements Luminaires with built-in transformers for filament lamps

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
149.79 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
14.98 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
44.94 €
Anglicky Hardcopy
In stock
149.79 €
Označení normy:BS EN 60598-2-6:1995
Počet stran:14
Vydáno:1995-02-15
ISBN:0 580 23730 3
Status:Standard
DESCRIPTION

BS EN 60598-2-6:1995


This standard BS EN 60598-2-6:1995 Luminaires. Particular requirements is classified in these ICS categories:
  • 29.140.40 Luminaires

This section of IEC 598-2 specifies requirements for luminaire with built-in transformers or convertors for filament lamps, with supply voltages and output voltages not exceeding:

  • 1 000 V for class I and class II luminaires and

  • 250 V for class 0 luminaires.

It is to be read in conjunction with those sections of IEC 598-1 to which reference is made.

This section does not apply to class III luminaires.

It is not necessary to use “Safety extra low voltage” (SELV) transformers or (SELV) convertors to comply with the requirements of this section. However, such transformers or convertors may satisfy the functional requirements of this section.

6.1.1 Normative references

The following normative documents contain provisions which, through reference in this text, constitute provisions of this section of IEC 598-2. At the time of publication, the editions indicated were valid. All normative documents are subject to revision, and parties to agreements based on this section of IEC 598-2 are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below.

Members of IEC and ISO maintain registers of currently valid International Standards.

IEC 417:1973, Graphical symbols for use on equipment.

IEC 598-1:1992, Luminaires — Part 1: General requirements and tests.

IEC 742:1983, Isolating transformers and safety isolating transformers — Requirements.

IEC 1046:1993, DC or a.c. supplied electronic step-down convertors for filament lamps — General and safety requirements.


For luminaires with supply voltages and output voltages not exceeding 1000 V for class I and class II luminaires, and 250 V for class 0 luminaires.