Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN 60719:1993 Calculation for the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
sklademVydáno: 1993-11-15
BS EN 60719:1993 Calculation for the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V

BS EN 60719:1993

Calculation for the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
149.79 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
14.98 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
44.94 €
Anglicky Hardcopy
In stock
149.79 €
Označení normy:BS EN 60719:1993
Počet stran:12
Vydáno:1993-11-15
ISBN:0 580 22591 7
Status:Standard
DESCRIPTION

BS EN 60719:1993


This standard BS EN 60719:1993 Calculation for the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V is classified in these ICS categories:
  • 29.060.20 Cables

This International Standard specifies a method for calculation of the lower and upper limits for the average outer diameter of cables and the outer dimensions of flat cords with circular copper conductors and of rated voltages up to and including 450/750 V.

This standard is not applicable to mineral insulated cables. The method shall not be used to calculate the diameter over the core assembly for determining the sheath thickness; the method given in Appendix A of IEC 502 shall be used for this purpose.

NOTE 1 It is stressed that the conductor diameters given in the tables are intended only for use in this standard as a basis for calculation and are not intended for verification by measurement.

NOTE 2 The factors given in 2.5 and 3.1 of this standard may be varied in preparing standards for cables in which the number of cores, the hardness of the insulation, precise positioning of the conductors or other factors may affect the dimensional tolerances permissible.


Not applicable to mineral insulated cables. For calculating the diameter over the core assembly for determining the sheath thickness, the method given in Appendix A of IEC 60502 should be used.