Homepage>BS EN 61000-4-14:1999+A2:2009 Electromagnetic compatibility (EMC) Testing and measurement techniques. Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase
Sponsored link
sklademVydáno: 2010-01-31
BS EN 61000-4-14:1999+A2:2009 Electromagnetic compatibility (EMC) Testing and measurement techniques. Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase

BS EN 61000-4-14:1999+A2:2009

Electromagnetic compatibility (EMC) Testing and measurement techniques. Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
194.98 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
19.50 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
58.49 €
Anglicky Hardcopy
In stock
194.98 €
Označení normy:BS EN 61000-4-14:1999+A2:2009
Počet stran:22
Vydáno:2010-01-31
ISBN:978 0 580 61440 8
Status:Standard
DESCRIPTION

BS EN 61000-4-14:1999+A2:2009


This standard BS EN 61000-4-14:1999+A2:2009 Electromagnetic compatibility (EMC) is classified in these ICS categories:
  • 27.160 Solar energy engineering
  • 33.100.20 Immunity

This part of IEC 61000 is a basic electromagnetic compatibility (EMC) publication. It considers immunity tests for electrical and/or electronic equipment in their electromagnetic environment. Only conducted phenomena are considered, including immunity tests for equipment connected to public and industrial power supply networks.

This part aims to establish a reference for evaluating the immunity of electric and electronic equipment when subjected to positive and negative low amplitude voltage fluctuations.

The voltage fluctuations considered by this standard do not include flicker, which is a physiological phenomenon due to lighting luminance fluctuations.

This standard applies to electrical and/or electronic equipment that have a rated input current up to 16 A per phase. It does not apply to electrical and/or electronic equipment connected to d.c. or a.c. 400 Hz distribution networks. Tests concerning these networks will be covered by other IEC standards.

The immunity test levels required for a specific electromagnetic environment, together with the performance criteria, are indicated in the product, product family or generic standards as applicable. However, most product groups do not have a history of being susceptible to voltage fluctuations. Consequently, testing for these phenomena is often not required.