Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN 61000-4-22:2011 Electromagnetic compatibility (EMC) Testing and measurement techniques. Radiated emission and immunity measurements in fully anechoic rooms (FARs)
Sponsored link
sklademVydáno: 2011-05-31
BS EN 61000-4-22:2011 Electromagnetic compatibility (EMC) Testing and measurement techniques. Radiated emission and immunity measurements in fully anechoic rooms (FARs)

BS EN 61000-4-22:2011

Electromagnetic compatibility (EMC) Testing and measurement techniques. Radiated emission and immunity measurements in fully anechoic rooms (FARs)

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
377.63 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
37.76 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
113.29 €
Anglicky Hardcopy
In stock
377.63 €
Označení normy:BS EN 61000-4-22:2011
Počet stran:54
Vydáno:2011-05-31
ISBN:978 0 580 61971 7
Status:Standard
DESCRIPTION

BS EN 61000-4-22:2011


This standard BS EN 61000-4-22:2011 Electromagnetic compatibility (EMC) is classified in these ICS categories:
  • 33.100.20 Immunity
  • 33.100.10 Emission
IEC 61000-4-22:2010 considers immunity tests and emission measurements for electric and/or electronic equipment. Only radiated phenomena are considered. It establishes the required test procedures for using fully anechoic rooms for performing radiated immunity testing and radiated emission measurements. IEC 61000-4-22:2010 establishes a common validation procedure, equipment under test (EUT) set-up requirements, and measurement methods for fully anechoic rooms (FARs) when both radiated electromagnetic emission measurements and radiated electromagnetic immunity tests will be performed in the same FAR. As a basic measurement standard, this part of IEC 61000 does not intend to specify the test levels or emission limits to be applied to particular apparatus or system(s). Its main goal is to provide general measurement procedures to all concerned product committees of IEC or CISPR. Specific product requirements and test conditions are defined by the responsible product committees. The methods described in this standard are appropriate for radiated emission measurements and immunity tests in the frequency range of 30 MHz to 18 GHz. IEC 61000-4-22:2010 has the status of a basic EMC publication in accordance with IEC Guide 107, Electromagnetic compatibility - Guide to the drafting of electromagnetic compatibility publications.