BS EN 61094-8:2012 Electroacoustics. Measurement microphones Methods for determining the free-field sensitivity of working standard microphones by comparison

BS EN 61094-8:2012

Electroacoustics. Measurement microphones Methods for determining the free-field sensitivity of working standard microphones by comparison

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
298.62 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
29.86 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
89.59 €
Anglicky Hardcopy
In stock
298.62 €
Označení normy:BS EN 61094-8:2012
Počet stran:34
Vydáno:2013-05-31
ISBN:978 0 580 82031 1
Status:Standard
DESCRIPTION

BS EN 61094-8:2012


This standard BS EN 61094-8:2012 Electroacoustics. Measurement microphones is classified in these ICS categories:
  • 17.140.50 Electroacoustics

This part of the IEC 61094 series is applicable to working standard microphones meeting the requirements of IEC 61094-4. It describes methods of determining the free-field sensitivity by comparison with a laboratory standard microphone or working standard microphone (where applicable) that has been calibrated according to either:

  • IEC 61094-3,

  • IEC 61094-2 or IEC 61094-5, and where factors given in IEC/TS 61094-7 have been applied,

  • IEC 61094-6,

  • this part of IEC 61094.

Methods performed in an acoustical environment that is a good approximation to an ideal free-field (e.g. a high quality free-field chamber), and methods that use post processing of results to minimise the effect of imperfections in the acoustical environment, to simulate free-field conditions, are both covered by this part of IEC 61094. Comparison methods based on the principles described in IEC 61094-3 are also possible but beyond the scope of this part of IEC 61094.

NOTE 1 This part of IEC 61094 is also applicable to laboratory standard microphones meeting the requirements of IEC 61094-1, noting that these microphones also meet the electroacoustic specifications for working standard microphones.

NOTE 2 This part of IEC 61094 is also applicable to combinations of microphone and preamplifier where the determined sensitivity is referred to the unloaded output voltage of the preamplifier.

NOTE 3 Other devices, for example, sound level meters can be calibrated using the principles of this part of IEC 61094, but are not within the scope of this standard.