Homepage>BS EN 62359:2011+A1:2018 Ultrasonics. Field characterization. Test methods for the determination of thermal and mechanical indices related to medical diagnostic ultrasonic fields
Sponsored link
sklademVydáno: 2018-06-27
BS EN 62359:2011+A1:2018 Ultrasonics. Field characterization. Test methods for the determination of thermal and mechanical indices related to medical diagnostic ultrasonic fields

BS EN 62359:2011+A1:2018

Ultrasonics. Field characterization. Test methods for the determination of thermal and mechanical indices related to medical diagnostic ultrasonic fields

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
407.25 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
40.73 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
122.18 €
Anglicky Hardcopy
In stock
407.25 €
Označení normy:BS EN 62359:2011+A1:2018
Počet stran:92
Vydáno:2018-06-27
ISBN:978 0 580 96877 8
Status:Standard
DESCRIPTION

BS EN 62359:2011+A1:2018


This standard BS EN 62359:2011+A1:2018 Ultrasonics. Field characterization. Test methods for the determination of thermal and mechanical indices related to medical diagnostic ultrasonic fields is classified in these ICS categories:
  • 17.140.50 Electroacoustics
  • 11.040.55 Diagnostic equipment

This International standard is applicable to medical diagnostic ultrasound fields.

This standard establishes

  • parameters related to thermal and non-thermal exposure aspects of diagnostic ultrasonic fields;

  • methods for the determination of an exposure parameter relating to temperature rise in theoretical tissue-equivalent models, resulting from absorption of ultrasound;

  • methods for the determination of an exposure parameter appropriate to certain non-thermal effects.

NOTE 1 In Clause 3 of this standard, SI units are used (per ISO/IEC Directives, Part 2, ed. 5, Annex I b) in the Notes below definitions of certain parameters, such as beam areas and intensities; it may be convenient to use decimal multiples or submultiples in practice. Users must take care of decimal prefixes used in combination with the units when using and calculating numerical data. For example, beam area may be specified in cm2 and intensities in W/cm2 or mW/cm2.

NOTE 2 Underlying calculations have been done from 0,25 MHz to 15 MHz for MI and 0,5 MHz to 15 MHz for TI.

NOTE 3 The thermal indices are steady state estimates based on the acoustic output power required to produce a 1°C temperature rise in tissue conforming to the “homogeneous tissue 0,3 dBcm-1MHz-1 attenuation model”[1]1) and may not be appropriate for radiation force imaging, or similar techniques that employ pulses or pulse bursts of sufficient duration to create a significant transient temperature rise. [2]