Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN IEC 60332-3-24:2018 Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category C
Sponsored link
sklademVydáno: 2018-10-19
BS EN IEC 60332-3-24:2018 Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category C

BS EN IEC 60332-3-24:2018

Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category C

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
183.58 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
18.36 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
55.07 €
Anglicky Hardcopy
In stock
183.58 €
Označení normy:BS EN IEC 60332-3-24:2018
Počet stran:20
Vydáno:2018-10-19
ISBN:978 0 580 94330 0
Status:Standard
DESCRIPTION

BS EN IEC 60332-3-24:2018


This standard BS EN IEC 60332-3-24:2018 Tests on electric and optical fibre cables under fire conditions is classified in these ICS categories:
  • 13.220.40 Ignitability and burning behaviour of materials and products
  • 33.180.10 Fibres and cables
  • 29.020 Electrical engineering in general
  • 29.060.20 Cables
  • 29.120.30 Plugs, socket-outlets, couplers

This part of IEC 60332 covers category C for methods of test for the assessment of vertical flame spread of vertically mounted bunched wires or cables, electrical or optical, under defined conditions.

This document relates to cables installed on the test ladder to achieve a nominal total volume of non-metallic material of 1,5 l/m of test sample. The flame application time is 20 min. The method of mounting uses the front of the standard ladder. The category is intended for general use where low volumes of non-metallic material are required to be evaluated.

The test is intended for type approval testing. The requirements for the selection of cables for testing are given in Annex A. The flame spread is measured as the extent of damage of the cable sample. This procedure can be used to demonstrate the cable’s ability to limit flame spread.

A recommended performance requirement is given in Annex B.

NOTE

For the purposes of this document the term "electric wire or cable" covers all insulated metallic conductor cables used for the conveyance of energy or signals.