Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN IEC 60793-1-54:2018 Optical fibres Measurement methods and test procedures. Gamma irradiation
Sponsored link
sklademVydáno: 2018-10-18
BS EN IEC 60793-1-54:2018 Optical fibres Measurement methods and test procedures. Gamma irradiation

BS EN IEC 60793-1-54:2018

Optical fibres Measurement methods and test procedures. Gamma irradiation

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
194.98 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
19.50 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
58.49 €
Anglicky Hardcopy
In stock
194.98 €
Označení normy:BS EN IEC 60793-1-54:2018
Počet stran:20
Vydáno:2018-10-18
ISBN:978 0 539 02660 3
Status:Standard
DESCRIPTION

BS EN IEC 60793-1-54:2018


This standard BS EN IEC 60793-1-54:2018 Optical fibres is classified in these ICS categories:
  • 33.180.10 Fibres and cables

This document outlines a method for measuring the steady state response of optical fibres and optical cables exposed to gamma radiation. It can be employed to determine the level of radiation-induced attenuation produced in Class B single-mode or Class A, category A1 and A2 multimode optical fibres, in either cabled or uncabled form, due to exposure to gamma radiation.

The attenuation of cabled and uncabled optical fibres generally increases when exposed to gamma radiation. This is primarily due to the trapping of radiolytic electrons and holes at defect sites in the glass (i.e. the formation of "colour centres"). This test procedure focuses on two regimes of interest: the low dose rate regime suitable for estimating the effect of environmental background radiation, and the high dose rate regime suitable for estimating the effect of adverse nuclear environments. The testing of the effects of environmental background radiation is achieved with an attenuation measurement approach similar to IEC 60793-1-40 method A, cut-back. The effects of adverse nuclear environments are tested by monitoring the power before, during and after exposure of the test sample to gamma radiation. The depopulation of colour centres by light (photo bleaching) or by heat causes recovery (lessening of radiation induced attenuation). Recovery can occur over a wide range of time which depends on the irradiation time and annealing temperature. This complicates the characterization of radiation induced attenuation since the attenuation depends on many variables including the temperature of the test environment, the configuration of the sample, the total dose and the dose rate applied to the sample and the light level used to measure it.

>This test is not a material test for the non-optical material components of a fibre optic cable. If degradation of cable materials exposed to irradiation is studied, other test methods will be used.

This test method is written to contain a clear, concise listing of instructions. The background knowledge that is necessary to perform correct, relevant and expressive irradiation tests as well as to limit measurement uncertainty is presented separately in IEC TR 62283.