Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN IEC 61674:2024 - TC Tracked Changes. Medical electrical equipment. Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging
Sponsored link
sklademVydáno: 2024-09-25
BS EN IEC 61674:2024 - TC Tracked Changes. Medical electrical equipment. Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging

BS EN IEC 61674:2024 - TC

Tracked Changes. Medical electrical equipment. Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
418.14 €
Anglicky Hardcopy
In stock
418.14 €
Označení normy:BS EN IEC 61674:2024 - TC
Počet stran:97
Vydáno:2024-09-25
ISBN:978 0 539 33484 5
Status:Tracked Changes
DESCRIPTION

BS EN IEC 61674:2024 - TC


This standard BS EN IEC 61674:2024 - TC Tracked Changes. Medical electrical equipment. Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging is classified in these ICS categories:
  • 11.040.50 Radiographic equipment
  • 17.240 Radiation measurements
IEC 61674:2024 specifies the performance and some related constructional requirements of DIAGNOSTIC DOSIMETERS intended for the measurement of AIR KERMA, AIR KERMA LENGTH PRODUCT or AIR KERMA RATE, in photon radiation fields used in medical X-ray imaging, such as RADIOGRAPHY, RADIOSCOPY and COMPUTED TOMOGRAPHY (CT), for X-RADIATION with generating potentials in the range of 20 kV to 150 kV. This document is applicable to the performance of DOSIMETERS with VENTED IONIZATION CHAMBERS and/or SEMICONDUCTOR DETECTORS as used in X-ray diagnostic imaging. IEC 61674:2024 cancels and replaces the second edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) for mammography, the manufacturer specifies the REFERENCE VALUE for the RADIATION QUALITY; b) for mammography, the manufacturer provides the MINIMUM RATED RANGE of RADIATION QUALITIES for the compliance test on energy dependence of response; c) the compliance test for analogue displays was removed; d) the compliance tests for range reset, the effect of leakage and recombination losses were removed. These tests are already covered by the test on linearity and cannot be conducted for modern devices. The estimation of COMBINED STANDARD UNCERTAINTY was changed accordingly; e) the compliance test for mains rechargeable and battery-operated dosimeters were updated for modern devices