Homepage>BS EN IEC 63045:2020 Ultrasonics. Non-focusing short pressure pulse sources including ballistic pressure pulse sources. Characteristics of fields
Sponsored link
sklademVydáno: 2020-07-27
BS EN IEC 63045:2020 Ultrasonics. Non-focusing short pressure pulse sources including ballistic pressure pulse sources. Characteristics of fields

BS EN IEC 63045:2020

Ultrasonics. Non-focusing short pressure pulse sources including ballistic pressure pulse sources. Characteristics of fields

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
354.92 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
35.49 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
106.48 €
Anglicky Hardcopy
In stock
354.92 €
Označení normy:BS EN IEC 63045:2020
Počet stran:68
Vydáno:2020-07-27
ISBN:978 0 580 97313 0
Status:Standard
DESCRIPTION

BS EN IEC 63045:2020


This standard BS EN IEC 63045:2020 Ultrasonics. Non-focusing short pressure pulse sources including ballistic pressure pulse sources. Characteristics of fields is classified in these ICS categories:
  • 17.140.50 Electroacoustics
IEC 63045:2020 is applicable to – therapy equipment using extracorporeally induced non-focused or weakly focused pressure pulses; – therapy equipment producing extracorporeally induced non-focused or weakly focused mechanical energy, where the pressure pulses are released as single events of duration up to 25 µs. This document does not apply to – therapy equipment using focusing pressure pulse sources such as extracorporeal lithotripsy equipment; – therapy equipment using other acoustic waveforms like physiotherapy equipment, low intensity ultrasound equipment and HIFU/HITU equipment. This document specifies – measurable parameters which are used in the declaration of the acoustic output of extracorporeal equipment producing a non-focused or weakly focused pressure pulse field, – methods of measurement and characterization of non-focused or weakly focused pressure pulse fields. This document has been developed for equipment intended for use in pressure pulse therapy, for example therapy of orthopaedic pain like shoulder pain, tennis elbow pain, heel spur pain, muscular trigger point therapy, lower back pain, etc. It is not intended to be used for extracorporeal lithotripsy equipment (as described in IEC 61846), physiotherapy equipment using other waveforms (as described in IEC 61689) and HIFU/HITU equipment (see IEC 60601 2-62 and IEC TR 62649).