Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN ISO 10703:2021 Water quality. Gamma-ray emitting radionuclides. Test method using high resolution gamma-ray spectrometry
Sponsored link
sklademVydáno: 2021-07-19
BS EN ISO 10703:2021 Water quality. Gamma-ray emitting radionuclides. Test method using high resolution gamma-ray spectrometry

BS EN ISO 10703:2021

Water quality. Gamma-ray emitting radionuclides. Test method using high resolution gamma-ray spectrometry

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
298.62 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
29.86 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
89.59 €
Anglicky Hardcopy
In stock
298.62 €
Označení normy:BS EN ISO 10703:2021
Počet stran:38
Vydáno:2021-07-19
ISBN:978 0 539 12163 6
Status:Standard
DESCRIPTION

BS EN ISO 10703:2021


This standard BS EN ISO 10703:2021 Water quality. Gamma-ray emitting radionuclides. Test method using high resolution gamma-ray spectrometry is classified in these ICS categories:
  • 17.240 Radiation measurements
  • 13.060.60 Examination of physical properties of water

This document specifies a method for the physical pre-treatment and conditioning of water samples and the determination of the activity concentration of various radionuclides emitting gamma-rays with energies between 40 keV and 2 MeV, by gamma?ray spectrometry according to the generic test method described in ISO 20042 .

The method is applicable to test samples of drinking water, rainwater, surface and ground water as well as cooling water, industrial water, domestic and industrial wastewater after proper sampling, sample handling, and test sample preparation (filtration when necessary and taking into account the amount of dissolved material in the water). This method is only applicable to homogeneous samples or samples which are homogeneous via timely filtration.

The lowest limit that can be measured without concentration of the sample or by using only passive shield of the detection system is about 5·10-2 Bq/l for e.g. 137Cs 1

1

The sample geometry: 3l Marinelli beaker; detector: GE HP N relative efficiency 55 % ; counting time: 18h.

. The upper limit of the activity corresponds to a dead time of 10 %. Higher dead times may be used but evidence of the accuracy of the dead-time correction is required.

Depending on different factors, such as the energy of the gamma-rays, the emission probability per nuclear disintegration, the size and geometry of the sample and the detector, the shielding, the counting time and other experimental parameters, the sample may require to be concentrated by evaporation if activities below 5·10-2 Bq/l need to be measured. However, volatile radionuclides (e.g. radon and radioiodine) can be lost during the source preparation.

This method is suitable for application in emergency situations.