Homepage>BS EN ISO 11691:2020 Acoustics. Measurement of insertion loss of ducted silencers without flow. Laboratory survey method
Sponsored link
sklademVydáno: 2020-12-02
BS EN ISO 11691:2020 Acoustics. Measurement of insertion loss of ducted silencers without flow. Laboratory survey method

BS EN ISO 11691:2020

Acoustics. Measurement of insertion loss of ducted silencers without flow. Laboratory survey method

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
194.33 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
19.43 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
58.30 €
Anglicky Hardcopy
In stock
194.33 €
Označení normy:BS EN ISO 11691:2020
Počet stran:18
Vydáno:2020-12-02
ISBN:978 0 539 02095 3
Status:Standard
DESCRIPTION

BS EN ISO 11691:2020


This standard BS EN ISO 11691:2020 Acoustics. Measurement of insertion loss of ducted silencers without flow. Laboratory survey method is classified in these ICS categories:
  • 91.120.20 Acoustics in building. Sound insulation
  • 91.140.30 Ventilation and air-conditioning systems
  • 17.140.20 Noise emitted by machines and equipment

This document specifies a laboratory substitution method to determine the insertion loss without flow of ducted, mainly absorbent, circular and rectangular silencers, as well as other duct elements for use in ventilating and air-conditioning systems.

NOTE

Laboratory measurement procedures for ducted silencers with superimposed flow are described in ISO 7235 [ 5 ].

This document is applicable to silencers where the design velocity does not exceed 15 m/s. As the method does not include self-generated flow noise, this document is not suitable for tests on silencers where this type of noise is of great importance for the evaluation of the silencer performance. As most silencers, particularly in offices and dwelling, have design velocities below 15 m/s, this document can often be a cost-efficient alternative to ISO 7235[ 5].

The insertion loss determined according to this document in a laboratory is not necessarily the same as the insertion loss obtained in an installation in the field. Different sound and flow fields in the duct yield different results. In this document, the sound field is dominated by plane wave modes. Due to the use of regular test ducts, the results can include some flanking transmission via structural vibrations in the duct walls that sets an upper limit to the insertion loss that can be determined.

This document is intended to be used for circular silencers with diameters of 80 mm to 2 000 mm or for rectangular silencers with cross-sectional areas within the same range.