Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN ISO 16017-2:2003 Indoor, ambient and workplace air. Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography Diffusive sampling
sklademVydáno: 2003-08-05
BS EN ISO 16017-2:2003 Indoor, ambient and workplace air. Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography Diffusive sampling

BS EN ISO 16017-2:2003

Indoor, ambient and workplace air. Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography Diffusive sampling

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
328.12 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
32.81 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
98.44 €
Anglicky Hardcopy
In stock
328.12 €
Označení normy:BS EN ISO 16017-2:2003
Počet stran:46
Vydáno:2003-08-05
ISBN:0 580 42022 1
Status:Standard
DESCRIPTION

BS EN ISO 16017-2:2003


This standard BS EN ISO 16017-2:2003 Indoor, ambient and workplace air. Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography is classified in these ICS categories:
  • 13.040.01 Air quality in general
  • 13.040.20 Ambient atmospheres
  • 13.040.30 Workplace atmospheres

This part of ISO 16017 gives general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air. It is applicable to indoor, ambient and workplace air.

This part of ISO 16017 is applicable to a wide range of vOCs, including hydrocarbons, halogenated hydrocarbons, esters, glycol ethers, ketones and alcohols. A number of sorbents1) are recommended for the sampling of these VOCs, each sorbent having a different range of applicability. very polar compounds generally require derivatisation; very low boiling compounds are only partially retained by the sorbents and can only be estimated qualitatively. Semi-volatile compounds are fully retained by the sorbents, but may only be partially recovered.

This part of ISO 16017 is applicable to the measurement of airborne vapours of VOCs in a mass concentration range of approximately 0,002 mg/m3 to 100 mg/m3 individual organic for an exposure time of 8 h, or 0,3 µg/m3 to 300 µg/m3 individual organic for an exposure time of four weeks.

The upper limit of the useful range is set by the sorptive capacity of the sorbent used and by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capability of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of analyte and/or interfering artefacts on the sorbent tubes. Artefacts are typically sub-nanogram for well-conditioned Tenax GR and carbonaceous sorbents such as Carbopack/Carbotrap type materials, carbonized molecular sieves such as Spherocarb and pure charcoals. Artefacts are typically at low nanogram levels for Tenax TA and at 5 ng to 50 ng levels for other porous polymers such as Chromosorbs and Porapaks.