Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN ISO 16645:2019 Radiological protection. Medical electron accelerators. Requirements and recommendations for shielding design and evaluation
Sponsored link
sklademVydáno: 2020-01-15
BS EN ISO 16645:2019 Radiological protection. Medical electron accelerators. Requirements and recommendations for shielding design and evaluation

BS EN ISO 16645:2019

Radiological protection. Medical electron accelerators. Requirements and recommendations for shielding design and evaluation

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
384.29 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
38.43 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
115.29 €
Anglicky Hardcopy
In stock
384.29 €
Označení normy:BS EN ISO 16645:2019
Počet stran:86
Vydáno:2020-01-15
ISBN:978 0 539 05736 2
Status:Standard
DESCRIPTION

BS EN ISO 16645:2019


This standard BS EN ISO 16645:2019 Radiological protection. Medical electron accelerators. Requirements and recommendations for shielding design and evaluation is classified in these ICS categories:
  • 13.280 Radiation protection

This International Standard is applicable to medical electron linear accelerators i.e. linear accelerators with nominal energies of the beam ranging from 4 MV to 30 MV, including particular installations such as robotic arm, helical intensity modulated radiotherapy devices and dedicated devices for intra operative radiotherapy (IORT) with electrons.

The cyclotrons and the synchrotrons used for hadrontherapy are not considered.

The radiation protection requirements and recommendations given in this International Standard cover the aspects relating to regulations, shielding design goals and other design criteria, role of the manufacturers, of the radiation protection officer or qualified expert and interactions between stakeholders, radiations around a linear accelerator, shielding for conventional and special devices (including shielding materials and transmission values, calculations for various treatment room configurations, duct impact on radiation protection) and the radiological monitoring (measurements).

NOTE 1 Annex A provides transmission values for the most common shielding materials.

NOTE 2 Annex B provides supporting data for shielding calculation.

NOTE 3 Annex C provides an example of calculation for conventional device and standard maze.