Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN ISO 19238:2023 Radiological protection. Performance criteria for service laboratories performing biological dosimetry by cytogenetics. Dicentric assay
Sponsored link
sklademVydáno: 2023-09-14
BS EN ISO 19238:2023 Radiological protection. Performance criteria for service laboratories performing biological dosimetry by cytogenetics. Dicentric assay

BS EN ISO 19238:2023

Radiological protection. Performance criteria for service laboratories performing biological dosimetry by cytogenetics. Dicentric assay

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
357.88 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
35.79 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
107.36 €
Anglicky Hardcopy
In stock
357.88 €
Označení normy:BS EN ISO 19238:2023
Počet stran:50
Vydáno:2023-09-14
ISBN:978 0 539 17632 2
Status:Standard
DESCRIPTION

BS EN ISO 19238:2023


This standard BS EN ISO 19238:2023 Radiological protection. Performance criteria for service laboratories performing biological dosimetry by cytogenetics. Dicentric assay is classified in these ICS categories:
  • 17.240 Radiation measurements
  • 13.280 Radiation protection
This document provides criteria for quality assurance and quality control, evaluation of the performance and the accreditation of biological dosimetry by cytogenetic service laboratories using the dicentric assay performed with manual scoring. This document is applicable to a)    the confidentiality of personal information, for the requestor and the service laboratory, b)    the laboratory safety requirements, c)    the calibration sources and calibration dose ranges useful for establishing the reference dose-response curves that contribute to the dose estimation from unstable chromosome aberration frequency and the detection limit, d)    the scoring procedure for unstable chromosome aberrations used for biological dosimetry, e)    the criteria for converting a measured aberration frequency into an estimate of absorbed dose, f)     the reporting of results, g)    the quality assurance and quality control, and h)    informative annexes containing sample instructions for requestor (see Annex A), sample questionnaire (see Annex B), sample report (see Annex C), fitting of the low dose-response curve by the method of maximum likelihood and calculating the error of the dose estimate (see Annex D), odds ratio method for cases of suspected exposure to a low dose (see Annex E), a method for determining the decision threshold and detection limit (see Annex F) and sample data sheet for recording aberrations (see Annex G).