Homepage>BS EN ISO 20046:2021 Radiological protection. Performance criteria for laboratories using Fluorescence In Situ Hybridization (FISH) translocation assay for assessment of exposure to ionizing radiation
sklademVydáno: 2021-02-23
BS EN ISO 20046:2021 Radiological protection. Performance criteria for laboratories using Fluorescence In Situ Hybridization (FISH) translocation assay for assessment of exposure to ionizing radiation

BS EN ISO 20046:2021

Radiological protection. Performance criteria for laboratories using Fluorescence In Situ Hybridization (FISH) translocation assay for assessment of exposure to ionizing radiation

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
328.12 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
32.81 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
98.44 €
Anglicky Hardcopy
In stock
328.12 €
Označení normy:BS EN ISO 20046:2021
Počet stran:50
Vydáno:2021-02-23
ISBN:978 0 539 14652 3
Status:Standard
DESCRIPTION

BS EN ISO 20046:2021


This standard BS EN ISO 20046:2021 Radiological protection. Performance criteria for laboratories using Fluorescence In Situ Hybridization (FISH) translocation assay for assessment of exposure to ionizing radiation is classified in these ICS categories:
  • 13.280 Radiation protection

The purpose of this document is to provide criteria for quality assurance (QA), quality control (QC) and evaluation of the performance of biological dosimetry by cytogenetic service laboratories.

This document addresses:

  1. the responsibilities of both the customer and the laboratory;

  2. the confidentiality of personal information, for the customer and the laboratory;

  3. the laboratory safety requirements;

  4. sample processing; culturing, staining and scoring, including the criteria for scoring for translocation analysis by FISH;

  5. the calibration sources and calibration dose ranges useful for establishing the reference dose‑response curves that contribute to the dose estimation from chromosome aberration frequency and the detection limit;

  6. the scoring procedure for translocations stained by FISH used for evaluation of exposure;

  7. the criteria for converting a measured aberration frequency into an estimate of absorbed dose (also appears as “dose”);

  8. the reporting of results;

  9. the QA and QC;

  10. Annexes A to F containing sample instructions for the customer, sample questionnaire, sample datasheet for recording aberrations, sample of report and fitting of the low dose-response curve by the method of maximum likelihood and calculating the uncertainty of dose estimate.