BS ISO 16063-34:2019 Methods for the calibration of vibration and shock transducers Testing of sensitivity at fixed temperatures

BS ISO 16063-34:2019

Methods for the calibration of vibration and shock transducers Testing of sensitivity at fixed temperatures

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
248.85 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
24.89 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
74.66 €
Anglicky Hardcopy
In stock
248.85 €
Označení normy:BS ISO 16063-34:2019
Počet stran:24
Vydáno:2020-04-09
ISBN:978 0 539 00756 5
Status:Standard
DESCRIPTION

BS ISO 16063-34:2019


This standard BS ISO 16063-34:2019 Methods for the calibration of vibration and shock transducers is classified in these ICS categories:
  • 17.160 Vibrations, shock and vibration measurements

This document details specifications for the instrumentation and methods to be used for testing fixed temperature sensitivity of vibration transducers. It applies to rectilinear velocity and acceleration transducers.

The methods specified use both a comparison to a reference transducer and an absolute measurement by laser interferometer.

This document is applicable for a frequency range from 10 Hz to 3 kHz (method-dependent), a dynamic range from 1 m/s2 to 100 m/s2 (frequency-dependent) and a temperature range from –1 90 °C to 800 °C (method-dependent). Although it is possible to achieve these ranges among all the described systems, generally each has limitations within them.

Method 1 (using a laser interferometer) is applicable to magnitude of sensitivity and phase calibration in the frequency range 10 Hz to 3 kHz at fixed temperatures (see Clause 7). Method 2 (using a reference transducer inside a chamber whose temperature limit is –70 °C to 500 °C) can be used for magnitude of sensitivity and phase calibration in the frequency range 10 Hz to 1 kHz at fixed temperatures (see Clause 8). Method 3 (using a reference transducer outside the chamber) can only be used for the determination of the temperature response of complex sensitivity over a certain temperature range (see Clause 9).

NOTE

Method 1 and Method 2 can provide the deviation of complex sensitivity over a certain temperature range if the calibration is also done at the reference temperature (room temperature 23 °C ± 5 °C).

To ensure the consistency of the use and test condition, the transducer, its cable and the conditioning amplifier are intended to be considered as a single unit and tested together.