Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS ISO 16200-2:2000 Workplace air quality. Sampling and analysis of volatile organic compounds by solvent desorption/gas chromatography Diffusive sampling method
Sponsored link
sklademVydáno: 2004-11-26
BS ISO 16200-2:2000 Workplace air quality. Sampling and analysis of volatile organic compounds by solvent desorption/gas chromatography Diffusive sampling method

BS ISO 16200-2:2000

Workplace air quality. Sampling and analysis of volatile organic compounds by solvent desorption/gas chromatography Diffusive sampling method

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
298.62 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
29.86 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
89.59 €
Anglicky Hardcopy
In stock
298.62 €
Označení normy:BS ISO 16200-2:2000
Počet stran:40
Vydáno:2004-11-26
ISBN:0 580 44877 0
Status:Standard
DESCRIPTION

BS ISO 16200-2:2000


This standard BS ISO 16200-2:2000 Workplace air quality. Sampling and analysis of volatile organic compounds by solvent desorption/gas chromatography is classified in these ICS categories:
  • 13.040.30 Workplace atmospheres

This part of ISO 16200 gives general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air.

This part of ISO 16200 is applicable to a wide range of VOCs, including hydrocarbons, halogenated hydrocarbons, esters, glycol ethers, ketones and alcohols. A number of devices and sorbents are recommended for the sampling of these VOCs, each sorbent having a different range of applicability.

NOTE Activated coconut shell charcoal is frequently used. Very polar compounds may require derivatization; very low boiling compounds will only be partially retained by the sorbents and can only be estimated qualitatively. Semi-volatile compounds will be fully retained by the sorbents, but may only be partially recovered.

This part of ISO 16200 is valid for the measurement of airborne vapours of VOCs in a concentration range of approximately 1 mg/m3 to 1000 mg/m3 individual organic for an exposure time of 8 h.

The upper limit of the useful range is set by the sorptive capacity of the sorbent used and, subject to dilution of the analysed solution, by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capability of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of analyte and/or interfering artefacts on the sampling devices or in the desorption solvent. Artefacts are typically sub-nanogram for activated charcoal, but higher levels of aromatic hydrocarbons have been noted in some batches.