BS ISO 17089-1:2019 Measurement of fluid flow in closed conduits. Ultrasonic meters for gas Meters for custody transfer and allocation measurement

BS ISO 17089-1:2019

Measurement of fluid flow in closed conduits. Ultrasonic meters for gas Meters for custody transfer and allocation measurement

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
407.25 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
40.73 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
122.18 €
Anglicky Hardcopy
In stock
407.25 €
Označení normy:BS ISO 17089-1:2019
Počet stran:126
Vydáno:2019-08-30
ISBN:978 0 580 90226 0
Status:Standard
DESCRIPTION

BS ISO 17089-1:2019


This standard BS ISO 17089-1:2019 Measurement of fluid flow in closed conduits. Ultrasonic meters for gas is classified in these ICS categories:
  • 17.120.10 Flow in closed conduits

This document specifies requirements and recommendations for ultrasonic gas flowmeters (USMs), which utilize the transit time of acoustic signals to measure the flow of single phase homogenous gases in closed conduits.

This document applies to transit time ultrasonic gas flowmeters used for custody transfer and allocation metering, such as full-bore, reduced-area, high-pressure, and low-pressure meters or any combination of these. There are no limits on the minimum or maximum sizes of the meter. This document can be applied to the measurement of almost any type of gas, such as air, natural gas, and ethane.

Included are flow measurement performance requirements for meters of two accuracy classes suitable for applications such as custody transfer and allocation measurement.

This document specifies construction, performance, calibration, diagnostics for meter verification, and output characteristics of ultrasonic meters for gas flow measurement and deals with installation conditions.

NOTE

It is possible that national or other regulations apply which can be more stringent than those in this document.