Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS ISO 20899:2018 Water quality. Plutonium and neptunium. Test method using ICP-MS
Sponsored link
sklademVydáno: 2018-09-04
BS ISO 20899:2018 Water quality. Plutonium and neptunium. Test method using ICP-MS

BS ISO 20899:2018

Water quality. Plutonium and neptunium. Test method using ICP-MS

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
194.33 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
19.43 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
58.30 €
Anglicky Hardcopy
In stock
194.33 €
Označení normy:BS ISO 20899:2018
Počet stran:22
Vydáno:2018-09-04
ISBN:978 0 580 93246 5
Status:Standard
DESCRIPTION

BS ISO 20899:2018


This standard BS ISO 20899:2018 Water quality. Plutonium and neptunium. Test method using ICP-MS is classified in these ICS categories:
  • 13.280 Radiation protection
  • 13.060.60 Examination of physical properties of water
  • 17.240 Radiation measurements

This document specifies methods used to determine the concentration of plutonium and neptunium isotopes in water by inductively coupled plasma mass spectrometry (ICP-MS) (239Pu,240Pu,241Pu and237Np). The concentrations obtained can be converted into activity concentrations of the different isotopes[9].

Due to its relatively short half-life and238U isobaric interference,238Pu can hardly be measured by this method. To quantify this isotope, other techniques can be used (ICP-MS with collision-reaction cell, ICP-MS/MS with collision-reaction cell or chemical separation). Alpha spectrometry measurement, as described in ISO 13167[10], is currently used[11].

This method is applicable to all types of water having a saline load less than 1 g·l−1. A dilution of the sample is possible to obtain a solution having a saline load and activity concentrations compatible with the preparation and the measurement assembly.

A filtration at 0,45 μm is needed for determination of dissolved nuclides. Acidification and chemical separation of the sample are always needed.

The limit of quantification depends on the chemical separation and the performance of the measurement device.

This method covers the measurement of those isotopes in water in activity concentrations between around[12][13]:

  • 1 mBq·l−1 to 5 Bq·l−1 for239Pu,240Pu and237Np;

  • 1 Bq·l−1 to 5 Bq·l−1 for241Pu.

In both cases, samples with higher activity concentrations than 5 Bq·l−1 can be measured if a dilution is performed before the chemical separation.

It is possible to measure241Pu following a pre-concentration step of at least 1 000.