Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>ČSN EN 15502-1+A1 - Kotle na plynná paliva pro ústřední vytápění - Část 1: Obecné požadavky a zkoušky
Sponsored link
Vydáno: 01.06.2024
ČSN EN 15502-1+A1 - Kotle na plynná paliva pro ústřední vytápění - Část 1: Obecné požadavky a zkoušky

ČSN EN 15502-1+A1

Kotle na plynná paliva pro ústřední vytápění - Část 1: Obecné požadavky a zkoušky

Format
Availability
Price and currency
Anglicky Hardcopy
In stock
55.73 €
Označení normy:ČSN EN 15502-1+A1
Třídící znak:075316
Počet stran:216
Vydáno:01.06.2024
Harmonizace:Norma není harmonizována
Katalogové číslo:519135
DESCRIPTION

ČSN EN 15502-1+A1

This document specifies the common requirements and test methods, as well as the classification, marking and energy labelling of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as "boilers". This document is to be used in conjunction with the specific Parts 2 (Part 2-1, Part 2-2 and following ones). This document applies to boilers of types B and C: NOTE - For further background information on appliance types see EN 1749:2020. a) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021; b) where the temperature of the water does not exceed 105 °C during normal operation; c) where the maximum operating pressure in the water circuit does not exceed 6 bar; d) which can give rise to condensation under certain circumstances; e) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler" or an "other boiler". If no declaration is given the boiler is to be considered both a "standard boiler" and an "other boiler"; f) which are intended to be installed inside a building or in a partially protected place; g) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit. This document applies to boilers designed for sealed water systems or for open water systems. NOTE - This general standard and the specific standards (see Part 2) provide requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard or a specific standard, the risk associated with this alternative construction will need to be assessed. An example of an assessment methodology, based upon risk assessment, is given in Clause 11. This document is not intended to cover appliances intended for connection to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB). This document does not cover all the requirements for : aa) appliances above 1000 kW; ab) appliances designed and constructed to burn gas containing carbon monoxide or other toxic components; ac) appliance having a supplementary heater.