Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>DD IEC/TS 62558:2011 Ultrasonics. Real-time pulse-echo scanners. Phantom with cylindrical, artificial cysts in tissue-mimicking material and method for evaluation and periodic testing of 3D-distributions of void-detectability ratio (VDR)
Sponsored link
sklademVydáno: 2011-06-30
DD IEC/TS 62558:2011 Ultrasonics. Real-time pulse-echo scanners. Phantom with cylindrical, artificial cysts in tissue-mimicking material and method for evaluation and periodic testing of 3D-distributions of void-detectability ratio (VDR)

DD IEC/TS 62558:2011

Ultrasonics. Real-time pulse-echo scanners. Phantom with cylindrical, artificial cysts in tissue-mimicking material and method for evaluation and periodic testing of 3D-distributions of void-detectability ratio (VDR)

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
354.57 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
35.46 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
106.37 €
Anglicky Hardcopy
In stock
354.57 €
Označení normy:DD IEC/TS 62558:2011
Počet stran:54
Vydáno:2011-06-30
ISBN:978 0 580 61959 5
Status:Standard
DESCRIPTION

DD IEC/TS 62558:2011


This standard DD IEC/TS 62558:2011 Ultrasonics. Real-time pulse-echo scanners. Phantom with cylindrical, artificial cysts in tissue-mimicking material and method for evaluation and periodic testing of 3D-distributions of void-detectability ratio (VDR) is classified in these ICS categories:
  • 11.040.55 Diagnostic equipment
  • 17.140.50 Electroacoustics
IEC/TS 62558:2011(E) specifies essential characteristics of a phantom and method for the measurement of void-detectability ratio for medical ultrasound systems and related transducers. It is restricted to the aspect of long-term reproducibility of testing results. Medical diagnostic ultrasound systems and related transducers need periodic testing as the quality of medical decisions based on ultrasonic images may decrease over time due to progressive degradation of essential systems characteristics. The TMM (Tissue Mimicking Material) phantom is intended to be used to measure and to enable documentation of changes in void-detectability ratio in periodic tests over years of use. This technical specification establishes:
- Important characteristics and requirements for a TMM 3D artificial cyst phantom using anechoic voids
- A design example of a 3D artificial cyst phantom, the necessary test equipment and use of relevant computer software algorithms.
This technical specification is currently applicable for linear array transducers. A uniformity test prior to void-detectability ratio (VDR) measurement is recommended.