Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>IEC 60317-44:1997 - Specifications for particular types of winding wires - Part 44: Aromatic polyimide tape wrapped rectangular copper wire, class 240
Sponsored link
sklademVydáno: 1997-03-27
IEC 60317-44:1997 - Specifications for particular types of winding wires - Part 44: Aromatic polyimide tape wrapped rectangular copper wire, class 240

IEC 60317-44:1997

Specifications for particular types of winding wires - Part 44: Aromatic polyimide tape wrapped rectangular copper wire, class 240

Spécifications pour types particuliers de fils de bobinage - Partie 44: Fil de section rectangulaire en cuivre recouvert d'un ruban de polyimide aromatique, classe 240

Format
Availability
Price and currency
Anglicky/Francouzsky Hardcopy
skladem
45.46 €
Anglicky/Francouzsky PDF
Immediate download
45.46 €
Označení normy:IEC 60317-44:1997
Vydáno:1997-03-27
Jazyk:Anglicky/Francouzsky
DESCRIPTION

IEC 60317-44:1997

IEC 60317-44:1997 specifies the requirements of tape wrapped rectangular copper winding wire of class 240. The insulation consists of one or two wrappings of aromatic polyimide tape. Class 240 is a thermal class that requires a temperature index of 240 and a heat shock temperature of at least 260 °C. NOTE In some countries, e.g. Canada, Russia, USA, this product is assigned a class 220. The tape is coated on one or both sides with a suitable adhesive, for instance, fluorinated ethylene propylene. After wrapping, the tape is heat-sealed to form a continuous and adherent sheath. Specific requirements may be subject to contract. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which the wire is recommended to be used and this will depend on many factors, including the types of equipment involved. The range of nominal conductor dimensions covered by this standard is: – width: min. 2,00 mm, max. 16,00 mm; – thickness: min. 0,80 mm, max. 5,60 mm. The specified combinations of width and thickness as well as the specified ratio width/thickness are given in IEC 60317-0-2. When a reference is made to winding wire according to this standard, the following information should be given: – reference to IEC 60317-44; – dimension of the nominal conductor (width x thickness); – grade. Example: 60317-44 IEC 4,00 mm x 1,00 mm grade A2