Homepage>IEC 60601-2-62:2013 - Medical electrical equipment - Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment
Sponsored link
sklademVydáno: 2013-07-09
IEC 60601-2-62:2013 - Medical electrical equipment - Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment

IEC 60601-2-62:2013

Medical electrical equipment - Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment

Appareils électromédicaux - Partie 2-62: Exigences particulières pour la sécurité de base et les performances essentielles des appareils ultrasonores thérapeutiques de haute intensité (HITU)

Format
Availability
Price and currency
Anglicky/Francouzsky Hardcopy
skladem
392.09 €
Anglicky/Francouzsky PDF
Immediate download
392.09 €
Označení normy:IEC 60601-2-62:2013
Vydáno:2013-07-09
Jazyk:Anglicky/Francouzsky
DESCRIPTION

IEC 60601-2-62:2013

IEC 60601-2-62:2013 applies to the basic safety and essential performance of HIGH INTENSITY THERAPEUTIC ULTRASOUND EQUIPMENT. This International Standard adds or replaces clauses listed in the IEC 60601-1 that are specific for HIGH INTENSITY THERAPEUTIC ULTRASOUND EQUIPMENT. If a clause or subclause is specifically intended to be applicable to such equipment only, or to related systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to individual equipment and to systems, as relevant. Hazards inherent in the intended physiological function of the equipment or systems within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. This standard can also be applied to - therapeutic equipment for thrombolysis through exposure to high-intensity therapeutic ultrasound; - therapeutic equipment for the treatment of occluding feeding vessels through exposure to high-intensity focused ultrasound; - and equipment intended to be used for relieving cancer pain due to bone metastases. This particular standard does not apply to - Ultrasound Equipment intended to be used for physiotherapy (use IEC 60601-2-5 and IEC 61689); - Ultrasound Equipment intended to be used for lithotripsy (use IEC 60601-2-36); - Ultrasound Equipment intended to be used for dedicated hyperthermia devices; and - Ultrasound Equipment intended to be used for phacoemulsification.