Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>IEC 61689:2022 - Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz
Sponsored link
sklademVydáno: 2022-03-08
IEC 61689:2022 - Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz

IEC 61689:2022

Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz

Ultrasons - Systèmes de physiothérapie - Spécifications des champs et méthodes de mesure dans la plage de fréquences de 0,5 MHz à 5 MHz

Format
Availability
Price and currency
Anglicky/Francouzsky Hardcopy
skladem
390.54 €
Anglicky/Francouzsky PDF
Immediate download
390.54 €
Označení normy:IEC 61689:2022
Vydáno:2022-03-08
Jazyk:Anglicky/Francouzsky
DESCRIPTION

IEC 61689:2022

IEC 61689:2022 is applicable to ultrasonic equipment designed for physiotherapy containing an ultrasonic transducer generating continuous or quasi-continuous (e.g. tone burst) wave ultrasound in the frequency range 0,5 MHz to 5 MHz. This document only relates to ultrasonic physiotherapy equipment employing a single plane non-focusing circular transducer per treatment head, producing static beams perpendicular to the face of the treatment head. This document specifies: - methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on reference testing methods; - characteristics to be specified by manufacturers of ultrasonic physiotherapy equipment based on reference testing methods; - guidelines for safety of the ultrasonic field generated by ultrasonic physiotherapy equipment; - methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on routine testing methods; - acceptance criteria for aspects of the output of ultrasonic physiotherapy equipment based on routine testing methods. Therapeutic value and methods of use of ultrasonic physiotherapy equipment are not within the scope of this document. Ultrasonic physiotherapy equipment using ultrasound in the frequency range from 20 kHz to 500 kHz is dealt with in IEC 63009. IEC 61689:2022 cancels and replaces the third edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition. a) The requirement on water oxygen content is specified in 6.1. b) Former recommendations in 6.2 have been changed to become requirements. c) Several definitions in Clause 3 have been updated in line with other TC 87 documents. d) The formerly informative Annex A has been changed to become normative, and now contains details on how conformance with IEC 60601-2-5 requirements is checked. e) Annex D has been considerably shortened and reference to a now withdrawn regulatory document has been removed.