Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>IEC TR 61901:2016 - Tests recommended on cables with a longitudinally applied metal foil for rated voltages above 30 kV (Um = 36 kV) up to and including 500 kV (Um = 550 kV)
Sponsored link
sklademVydáno: 2016-05-18
IEC TR 61901:2016 - Tests recommended on cables with a longitudinally applied metal foil for rated voltages above 30 kV (Um = 36 kV) up to and including 500 kV (Um = 550 kV)

IEC TR 61901:2016

Tests recommended on cables with a longitudinally applied metal foil for rated voltages above 30 kV (Um = 36 kV) up to and including 500 kV (Um = 550 kV)

Format
Availability
Price and currency
Anglicky Hardcopy
skladem
169.20 €
Anglicky PDF
Immediate download
169.20 €
Označení normy:IEC TR 61901:2016
Vydáno:2016-05-18
Jazyk:Anglicky
DESCRIPTION

IEC TR 61901:2016

IEC TR 61901:2016(E), which is a Technical Report, specifies test methods and requirements for power cable systems, cables with extruded insulation and their accessories for fixed installations, for rated voltages above 30 kV (Um = 36 kV) up to and including 500 kV (Um = 550 kV). The requirements apply to single-core cables and to their accessories for usual conditions of installation and operation, but not to special cables and their accessories, such as submarine cables, for which modifications to the tests may be necessary or special test conditions may need to be devised. This edition includes the following significant technical changes with respect to the previous edition: a) Recommendations on the tests to be performed at the different stages of the cable and cable system qualification (development tests, type tests, sample tests, routine tests, after installation tests) have been provided; b) The performance level of the tests related to the longitudinally applied metal foil which depends on the cable design has been detailed; c) Three cable designs that represent the world production of cables with longitudinally applied metal foil have been detailed; d) A test on the weld design has been included, following the appearance of a new cable design with smooth and longitudinally welded aluminium foil (referred to in this document as combined design); e) An examination of the cable at the end of the type test has been included; f) The cable system approach (cable with installed accessories) has been considered and a short circuit test with accessories has been introduced.