Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>PD 7974-3:2019 Application of fire safety engineering principles to the design of buildings Structural response to fire and fire spread beyond the enclosure of origin (Sub-system 3)
Sponsored link
sklademVydáno: 2019-03-27
PD 7974-3:2019 Application of fire safety engineering principles to the design of buildings Structural response to fire and fire spread beyond the enclosure of origin (Sub-system 3)

PD 7974-3:2019

Application of fire safety engineering principles to the design of buildings Structural response to fire and fire spread beyond the enclosure of origin (Sub-system 3)

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
407.25 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
40.73 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
122.18 €
Anglicky Hardcopy
In stock
407.25 €
Označení normy:PD 7974-3:2019
Počet stran:128
Vydáno:2019-03-27
ISBN:978 0 580 97727 5
Status:Standard
DESCRIPTION

PD 7974-3:2019


This standard PD 7974-3:2019 Application of fire safety engineering principles to the design of buildings is classified in these ICS categories:
  • 91.040.01 Buildings in general
  • 13.220.20 Fire protection

This Published Document provides a framework for developing a rational methodology for design using a fire safety engineering approach through the application of scientific and engineering principles to the protection of people, property and the environment from fire. This Published Document considers the following issues:

  1. the conditions that lead to fire spread beyond the enclosure of fire origin (see also Annex A);

  2. the selection of design fires depending on the objectives of the assessment (see also Annex B);

  3. the thermal and mechanical response of the enclosure boundaries and its structure to the fire conditions (see also Annex C and Annex D);

  4. the impact of the anticipated thermal and mechanical responses on adjacent enclosures and spaces; and

  5. the structural responses of loadbearing elements and their effect on structural stability, load transfer and acceptable damage according to the design and purpose of the building (see also Annex E and Annex F).

Annex G provides a methodology for establishing the extended application of fire resistance test results.