Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>PD CEN/TS 14807:2013 Plastics piping systems. Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP). Guidance for the structural analysis of buried GRP-UP pipelines
Sponsored link
sklademVydáno: 2013-12-31
PD CEN/TS 14807:2013 Plastics piping systems. Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP). Guidance for the structural analysis of buried GRP-UP pipelines

PD CEN/TS 14807:2013

Plastics piping systems. Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP). Guidance for the structural analysis of buried GRP-UP pipelines

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
190.48 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
19.05 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
57.14 €
Anglicky Hardcopy
In stock
190.48 €
Označení normy:PD CEN/TS 14807:2013
Počet stran:16
Vydáno:2013-12-31
ISBN:978 0 580 82218 6
Status:Standard
DESCRIPTION

PD CEN/TS 14807:2013


This standard PD CEN/TS 14807:2013 Plastics piping systems. Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP). Guidance for the structural analysis of buried GRP-UP pipelines is classified in these ICS categories:
  • 93.030 External sewage systems
  • 91.140.60 Water supply systems
  • 91.140.80 Drainage systems

This Technical Specification, which is a guidance document for use with a structural analy sis procedure for below ground installations, covers limits applicable to glass -reinforced thermosetting plastics (GRP) pipes used for the conveyance of liquids under pressure or gravity conditions.

This document does not specify a particular structural analysis procedure but gives guidance on the selection of a structural analysis procedure. It concludes that any established structural analysis procedure may be used provided it includes the assessment of short and long -term deflection and buckling resistan ce.

Products complying to the applicable GRP product standards EN 1796 or EN 14364, which are not subject to internal pressure, are suitable as long as the analysis shows that the long -term deflection of the installed pipes is limited to 6 %, which is the basic assumption of the GRP pipe product standards. Products complying with the applicable system standards (EN 1796 or EN 14364), which are subject to internal pressure, are suitable as long as the analysis shows that the initial deflection of the installed pipes does not exceed 3 %.

NOTE The approach followed when preparing a general structural analysis procedure does not depend on the nominal size(s) of the pipe(s).

A suitable structural analysis procedure should normally be capable of being used for pipes operatin g at different temperatures provided that the corresponding temperature re -rating factors for the relevant pipe properties are applied, as specified in the referring standard(s). Nevertheless, high service temperatures may require an additional analysis of the longitudinal stresses and strains and/or a special design of the joints.

Normal structural analysis procedures are intended to cover normal soil installation conditions. Pipes to be designed for installations in abnormal or unusual conditions, e.g. in quick soils or a marine sea-bed, may require special engineering. Some structural analysis procedures may include axial effects depending upon the type of joint used.