Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>PD CEN/TS 15502-3-1:2024 Gas-fired central heating boilers H2NG and ACCF. Expansion of EN 15502-2-1:2022
Sponsored link
sklademVydáno: 2024-05-20
PD CEN/TS 15502-3-1:2024 Gas-fired central heating boilers H2NG and ACCF. Expansion of EN 15502-2-1:2022

PD CEN/TS 15502-3-1:2024

Gas-fired central heating boilers H2NG and ACCF. Expansion of EN 15502-2-1:2022

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
354.57 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
35.46 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
106.37 €
Anglicky Hardcopy
In stock
354.57 €
Označení normy:PD CEN/TS 15502-3-1:2024
Počet stran:62
Vydáno:2024-05-20
ISBN:978 0 539 28678 6
Status:Standard
DESCRIPTION

PD CEN/TS 15502-3-1:2024


This standard PD CEN/TS 15502-3-1:2024 Gas-fired central heating boilers is classified in these ICS categories:
  • 27.060.30 Boilers and heat exchangers
  • 27.075 Hydrogen technologies
  • 91.140.10 Central heating systems
Scope of CEN/TS 15502-3-1 EN 15502-2-1:2022, Clause 1 applies with the following modifications: Add after k): l) which are fully premixed appliances equipped with an Adaptive Combustion Control Function (ACCF) that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance including gas grids for natural gases of the second family where up to 20% hydrogen volume is added to the natural gas (H2NG-Y20). m) which are fully premixed appliances equipped with a Pneumatic Gas Air Ratio controller (PGAR) that are intended to be connected to gas grids for natural gases of the second family where up to 20% hydrogen volume is added to the natural gas (H2NG-Y20), where the quality of the distributed gas without adding the hydrogen is not likely to vary to a large extent over the lifetime of the appliance. Replace ab) and ak) and al) by the following: ab) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB of EN 15502-1:2021), except for fully premixed appliances with a ACCF, as ACCF appliances are designed to adapt to variations in gas quality. ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas, except for fully premixed appliances with a ACCF or PGAR (which are covered by this document); al) Partially premixed appliances equipped with an adaptive combustion control function (ACCF).