PD CEN/TS 17286:2019 Stationary source emissions. Mercury monitoring using sorbent traps

PD CEN/TS 17286:2019

Stationary source emissions. Mercury monitoring using sorbent traps

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
355.76 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
35.58 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
106.73 €
Anglicky Hardcopy
In stock
355.76 €
Označení normy:PD CEN/TS 17286:2019
Počet stran:66
Vydáno:2019-05-13
ISBN:978 0 539 04942 8
Status:Standard
DESCRIPTION

PD CEN/TS 17286:2019


This standard PD CEN/TS 17286:2019 Stationary source emissions. Mercury monitoring using sorbent traps is classified in these ICS categories:
  • 13.040.40 Stationary source emissions

The purpose of this document is to establish performance benchmarks for, and to evaluate the acceptability of, sorbent trap monitoring systems used to monitor total vapour- phase mercury (Hg) emissions in stationary source flue gas streams. These monitoring systems involve continuous repetitive in-flue sampling using paired sorbent traps with subsequent analysis of the time-integrated samples.

This document is suitable for both short-term (periodic) measurements and long-term (continuous) monitoring using sorbent traps.

NOTE When this Technical Specification has been validated, the sorbent trap method will be an Alternative Method subject to the restrictions on applicability defined below. Until that time, EN 13211 is the only accepted Reference Method for both short-term (periodic) measurements and for calibrating continuous monitoring systems, including those with long-term sampling systems. EN 13211 is a wet chemistry approach that relies on absorption of mercury into impinger solutions.

The substance measured according to this specification is the total vapour phase mercury in the flue gas, which represents the sum of the elemental mercury (Hg0) and gaseous forms of oxidized mercury (Hg2+), such as mercury (II) chloride, in mass concentration units of micrograms (μg) per dry meter cubed (m3). The analytical range is typically 0,1 to greater than 50 μg/m3.

The sorbent tube approach is intended for use under relatively low particulate conditions (typically less than 100 mg/m3) when monitoring downstream of all pollution control devices, e.g. at coal fired power plants and cement plants. In this case, the contribution of mercury in the particulate fraction is considered to be negligible (typically less than 5 % of total mercury). However, it shall be noted that the sorbent trap does take account of the finest particle fraction that is sampled with the flue gas, in addition to capturing the vapour phase mercury.

This specification also contains routine procedures and specifications that are designed to evaluate the ongoing performance of an installed sorbent trap monitoring system. The operator of the industrial installation is responsible for the correct calibration, maintenance and operation of this long-term sampling system. Additional requirements for calibration and quality assurance of the long-term sampling system are then defined in EN 14884 and EN 14181.