Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>PD CEN/TS 18094:2024 Non-destructive testing. Test method for determining residual stresses by synchrotron x-ray diffraction
Sponsored link
sklademVydáno: 2024-12-23
PD CEN/TS 18094:2024 Non-destructive testing. Test method for determining residual stresses by synchrotron x-ray diffraction

PD CEN/TS 18094:2024

Non-destructive testing. Test method for determining residual stresses by synchrotron x-ray diffraction

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
377.70 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
37.77 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
113.31 €
Anglicky Hardcopy
In stock
377.70 €
Označení normy:PD CEN/TS 18094:2024
Počet stran:52
Vydáno:2024-12-23
ISBN:978 0 539 31204 1
Status:Standard
DESCRIPTION

PD CEN/TS 18094:2024


This standard PD CEN/TS 18094:2024 Non-destructive testing. Test method for determining residual stresses by synchrotron x-ray diffraction is classified in these ICS categories:
  • 19.100 Non-destructive testing
This document describes the test method for determining residual stresses in polycrystalline materials by the synchrotron X-ray diffraction method. The method can be applied to both homogeneous and inhomogeneous materials including those containing distinct phases. Information on how to carry out residual stress measurements by the synchrotron X-ray diffraction technique is provided as: - the selection of appropriate diffracting lattice planes on which measurements should be made for different categories of materials, - the specimen directions in which the measurements should be performed, - the volume of material examined in relation to the material grain size and the envisaged stress state, - the selection of the stress-free reference (sample) facilitating the residual strain calculation, and - the methods available for deriving residual stresses from the measured strain data. Procedures are presented for calibrating synchrotron X-ray diffraction instruments, enabling: - accurately positioning and aligning test pieces; - precisely defining the volume of material sampled for the individual measurements; and also for: - making measurements; - carrying out procedures for analysing the results; - determining their uncertainties. The principles of the synchrotron X-ray diffraction technique are described and put into perspective with EN 15305:2008 and EN ISO 21432:2020, which are used to measure stresses in the bulk of a specimen.