Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>PD CEN/TS 1948-5:2015 Stationary source emissions. Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs Long-term sampling of PCDDs/PCDFs and PCBs
sklademVydáno: 2015-04-30
PD CEN/TS 1948-5:2015 Stationary source emissions. Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs Long-term sampling of PCDDs/PCDFs and PCBs

PD CEN/TS 1948-5:2015

Stationary source emissions. Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs Long-term sampling of PCDDs/PCDFs and PCBs

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
373.88 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
37.39 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
112.16 €
Anglicky Hardcopy
In stock
373.88 €
Označení normy:PD CEN/TS 1948-5:2015
Počet stran:84
Vydáno:2015-04-30
ISBN:978 0 580 85314 2
Status:Standard
DESCRIPTION

PD CEN/TS 1948-5:2015


This standard PD CEN/TS 1948-5:2015 Stationary source emissions. Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs is classified in these ICS categories:
  • 13.040.40 Stationary source emissions

This Technical Specification specifies the long-term sampling of PCDDs, PCDFs and PCBs. There are three different sampling methods, which use the three different principles described in EN 1948‑1 modified for long-term sampling requirements:

  • filter/condenser method;

  • dilution method;

  • cooled probe method.

Each sampling method is illustrated in detail in Annex D. The sampling methods described in this document are designed for a sampling duration of typically four weeks.

Additionally this document specifies a framework of quality control requirements for any long-term sampling method to be applied (see Annex C and Annex F).

With the methods described experiences were gained for a concentration range from typically 0,003 ng I-TEQ/m 3 up to 4,0 ng I-TEQ/m 3 and 0,003 ng WHO-TEQ/m 3 up to 4,0 ng WHO-TEQ/m 3 respectively at different stationary sources (e.g. waste incinerators, sinter plants, cement kilns).

For the complete measurement method the use of EN 1948‑2 and EN 1948‑3 describing extraction and cleanup and identification and quantification, respectively, is necessary in order to determine PCDDs/PCDFs. Also EN 1948‑4 is necessary for the analyses of dioxin-like PCBs.