Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>PD CLC IEC/TS 60079-39:2019 Explosive atmospheres Intrinsically safe systems with electronically controlled spark duration limitation
sklademVydáno: 2020-11-06
PD CLC IEC/TS 60079-39:2019 Explosive atmospheres Intrinsically safe systems with electronically controlled spark duration limitation

PD CLC IEC/TS 60079-39:2019

Explosive atmospheres Intrinsically safe systems with electronically controlled spark duration limitation

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
344.76 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
34.48 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
103.43 €
Anglicky Hardcopy
In stock
344.76 €
Označení normy:PD CLC IEC/TS 60079-39:2019
Počet stran:58
Vydáno:2020-11-06
ISBN:978 0 539 15871 7
Status:Standard
DESCRIPTION

PD CLC IEC/TS 60079-39:2019


This standard PD CLC IEC/TS 60079-39:2019 Explosive atmospheres is classified in these ICS categories:
  • 29.260.20 Electrical apparatus for explosive atmospheres

This Technical Specification specifies the construction, testing, installation and maintenance of Power-i apparatus and systems which utilise electronically controlled spark duration limitation to maintain an adequate level of intrinsic safety.

This Technical Specification contains requirements for intrinsically safe apparatus and wiring intended for use in explosive atmospheres and for associated apparatus intended for connection to intrinsically safe circuits entering such atmospheres.

This Technical Specification excludes the level of protection “ia” and the use of softwarecontrolled circuits.

This Technical Specification applies to electrical equipment utilising voltages not higher than 40 V d.c. and a safety factor 1,5 for Groups IIB, IIA, I and III. It is also applicable to Group IIC “ic” apparatus with a safety factor 1,0. Group IIC “ib” apparatus with a safety factor 1,5 are restricted to voltages up to 32 V d.c.

This type of protection is applicable to electrical equipment in which the electrical circuits themselves are incapable of causing an explosion of the surrounding explosive atmospheres.

This Technical Specification is applicable to intrinsically safe apparatus and systems which utilise electronically controlled spark duration limitation with the aim of providing more electrical power while maintaining an adequate level of safety.

This Technical Specification is also applicable to electrical equipment or parts of electrical equipment located outside hazardous areas or protected by another type of protection listed in the IEC 60079 series, where the intrinsic safety of the electrical circuits in explosive atmospheres depends on the design and construction of such electrical equipment or parts of such electrical equipment. The electrical circuits located in the hazardous area are evaluated for use in such locations by applying this Technical Specification.

This Technical Specification supplements and modifies the requirements of IEC 60079-0, IEC 60079-11, IEC 60079-14, IEC 60079-17 and IEC 60079-25.