Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>PD IEC/TR 60909-2:2008 Short-circuit currents in three-phase a.c. systems Data of electrical equipment for short-circuit current calculations
Sponsored link
sklademVydáno: 2008-11-13
PD IEC/TR 60909-2:2008 Short-circuit currents in three-phase a.c. systems Data of electrical equipment for short-circuit current calculations

PD IEC/TR 60909-2:2008

Short-circuit currents in three-phase a.c. systems Data of electrical equipment for short-circuit current calculations

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
357.88 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
35.79 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
107.36 €
Anglicky Hardcopy
In stock
357.88 €
Označení normy:PD IEC/TR 60909-2:2008
Počet stran:50
Vydáno:2008-11-13
ISBN:978 0 580 62329 5
Status:Standard
DESCRIPTION

PD IEC/TR 60909-2:2008


This standard PD IEC/TR 60909-2:2008 Short-circuit currents in three-phase a.c. systems is classified in these ICS categories:
  • 29.020 Electrical engineering in general
  • 17.220.01 Electricity. Magnetism. General aspects
  • 29.240.20 Power transmission and distribution lines

This part of IEC 60909 comprises data of electrical equipment collected from different countries to be used when necessary for the calculation of short-circuit currents in accordance with IEC 60909-0.

Generally, electrical equipment data are given by the manufacturers on the name plate or by the electricity supplier.

In some cases, however, the data may not be available. The data in this report may be applied for calculating short-circuit currents in low-voltage networks if they are in accordance with typical equipment employed in the user’s country. The collected data and their evaluation may be used for medium- or high-voltage planning purposes and also for comparison with data given by manufacturers or electricity suppliers. For overhead lines and cables the electrical data may in some cases also be calculated from the physical dimensions and the material following the equations given in this report.

Thus this technical report is an addition to IEC 60909-0. It does not, however, change the basis for the standardized calculation procedure given in IEC 60909-0 and IEC 60909-3.