Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>PD IEC TR 61850-90-4:2020 Communication networks and systems for power utility automation Network engineering guidelines
Sponsored link
sklademVydáno: 2020-06-08
PD IEC TR 61850-90-4:2020 Communication networks and systems for power utility automation Network engineering guidelines

PD IEC TR 61850-90-4:2020

Communication networks and systems for power utility automation Network engineering guidelines

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
383.91 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
38.39 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
115.17 €
Anglicky Hardcopy
In stock
383.91 €
Označení normy:PD IEC TR 61850-90-4:2020
Počet stran:362
Vydáno:2020-06-08
ISBN:978 0 539 14186 3
Status:Standard
DESCRIPTION

PD IEC TR 61850-90-4:2020


This standard PD IEC TR 61850-90-4:2020 Communication networks and systems for power utility automation is classified in these ICS categories:
  • 33.200 Telecontrol. Telemetering

1.1 General

This part of IEC 61850, which is a Technical Report, is intended for an audience familiar with network communication and/or IEC 61850-based systems and particularly for substation protection and control equipment vendors, network equipment vendors and system integrators.

This document focuses on engineering a local area network limited to the requirements of IEC 61850-based substation automation. It outlines the advantages and disadvantages of different approaches to network topology, redundancy, clock synchronization, etc. so that the network designer can make educated decisions. In addition, this document outlines possible improvements to both substation automation and networking equipment.

This document addresses data transfer over the network in IEC 61850, such as transmitting tripping commands for protection via GOOSE messages, and in particular the multicast data transfer of large volumes of sampled values (SV) from merging units (MUs).

This document considers seamless redundancy to increase the network availability under failure conditions and the high precision clock synchronization that is central to the process bus and synchrophasor operation.

This document is not intended as a tutorial on networking or on IEC 61850. Rather, it references and summarizes standards and publications to assist the engineers. Many publications discuss the Ethernet technology but do not address the networks in terms of substation automation. Therefore, many technologies and options have been ignored since they were not considered relevant for a future-proof substation automation network design.

This document does not address network-based security, which is the subject of IEC 62351 and IEC 62443.

This document does not address technologies for wide area networks; these are covered by IEC TR 61850-90-12. Guidelines for communication outside of the substation that uses exclusively the routable Internet Protocol have been published, especially in documents IEC TR 61850-90-1 (substation to substation), IEC TR 61850-90-2 (substation to control center) and IEC TR 61850-90-5 (synchrophasor transmission). However, data flows used in substationto- substation communication, or substation-to-control centre communication such as R-GOOSE and R-SV are covered when they transit over Ethernet links within the substation.

This document does not dispense the responsible system integrator from an analysis of the actual application configuration, which is the base for a dependable system.