Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>PD ISO/TR 12470-2:2017 Fire-resistance tests. Guidance on the application and extension of results from tests conducted on fire containment assemblies and products Non-loadbearing elements
Sponsored link
sklademVydáno: 2017-12-07
PD ISO/TR 12470-2:2017 Fire-resistance tests. Guidance on the application and extension of results from tests conducted on fire containment assemblies and products Non-loadbearing elements

PD ISO/TR 12470-2:2017

Fire-resistance tests. Guidance on the application and extension of results from tests conducted on fire containment assemblies and products Non-loadbearing elements

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
407.25 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
40.73 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
122.18 €
Anglicky Hardcopy
In stock
407.25 €
Označení normy:PD ISO/TR 12470-2:2017
Počet stran:80
Vydáno:2017-12-07
ISBN:978 0 580 95159 6
Status:Standard
DESCRIPTION

PD ISO/TR 12470-2:2017


This standard PD ISO/TR 12470-2:2017 Fire-resistance tests. Guidance on the application and extension of results from tests conducted on fire containment assemblies and products is classified in these ICS categories:
  • 13.220.40 Ignitability and burning behaviour of materials and products
  • 13.220.50 Fire-resistance of building materials and elements

This document explains a methodology to determine the applicability of the results of fire resistance tests to actual applications.

It is applicable to those non-loadbearing elements for which there is an ISO standard test procedure based upon the ISO 834 series for determining the fire resistance of a representative sample of the construction proposed for use in a specific building or just for general use. These elements are:

  • fire resisting door assemblies (excluding lift landing doorsets):

    • timber;

    • steel;

  • fire resisting vertical glazing – metal framed:

    NOTE The rheology of glass is such that gravity has a disproportional influence on fire glass when it is heated to high temperatures and as a consequence, it is not possible to provide generic guidance on the extended application of horizontal glazed elements.

    • timber framed;

  • linear gap sealing;

  • service penetration sealing.

Fire resistance testing furnaces have fairly restricted size limitations and as a consequence, there is little confidence that the result obtained on an element of construction tested in accordance with the standard methods will behave in a similar manner when installed in the final building.

Direct and extended applications of test results are the two possible ways to ensure that an element that is not identical to the tested construction will have an acceptable probability of obtaining the same fire rating as that of the original tested specimen. In both cases, these applications generally refer only to the fire rating that the building element can expect to reach if it, or a representative sample of it, were to be tested in a furnace according to the standard fire test conditions used in the reference test.

The criteria and methodology used in evaluating ductwork and dampers is significantly different from those used to evaluate conventional separating elements and for this reason, these forms of construction are not included in the scope of this document. It is planned that a subsequent part of this document may include guidance on these elements.