Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>PD ISO/TS 6336-4:2019 Calculation of load capacity of spur and helical gears Calculation of tooth flank fracture load capacity
sklademVydáno: 2019-08-23
PD ISO/TS 6336-4:2019 Calculation of load capacity of spur and helical gears Calculation of tooth flank fracture load capacity

PD ISO/TS 6336-4:2019

Calculation of load capacity of spur and helical gears Calculation of tooth flank fracture load capacity

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
290.07 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
29.01 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
87.02 €
Anglicky Hardcopy
In stock
290.07 €
Označení normy:PD ISO/TS 6336-4:2019
Počet stran:38
Vydáno:2019-08-23
ISBN:978 0 539 06150 5
Status:Standard
DESCRIPTION

PD ISO/TS 6336-4:2019


This standard PD ISO/TS 6336-4:2019 Calculation of load capacity of spur and helical gears is classified in these ICS categories:
  • 21.200 Gears

This document describes a procedure for the calculation of the tooth flank fracture load capacity of cylindrical spur and helical gears with external teeth.

It is not intended to be used as a rating method in the design and certification process of a gearbox.

The formulae specified are applicable for driving as well as for driven cylindrical gears while the tooth profiles are in accordance with the basic rack specified in ISO 53. They can also be used for teeth conjugate to other racks where the actual transverse contact ratio is less than εα = 2,5. The procedure was validated for case carburized[15] gears and the formulae of this document are only applicable to case carburized gears with specifications inside the following limits:

  • Hertzian stress: 500 N/mm2 ≤ pH ≤ 3 000 N/mm2;

  • Normal radius of relative curvature: 5 mm ≤ ρred ≤ 150 mm;

  • Case hardening depth at 550 HV in finished condition: 0,3 mm ≤ CHD ≤ 4,5 mm.

This document is not applicable for the assessment of types of gear tooth damage other than tooth flank fracture.