Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>IEC 60229:2007 - Electric cables - Tests on extruded oversheaths with a special protective function
Sponsored link
sklademVydáno: 2007-10-10
IEC 60229:2007 - Electric cables - Tests on extruded oversheaths with a special protective function

IEC 60229:2007

Electric cables - Tests on extruded oversheaths with a special protective function

Câbles électriques - Essais sur les gaines extérieures extrudées avec fonction spéciale de protection

Formát
Dostupnost
Cena a měna
Anglicky/Francouzsky Tisk
skladem
1144 Kč
Anglicky/Francouzsky PDF
K okamžitému stažení
1144 Kč
Označení normy:IEC 60229:2007
Vydáno:2007-10-10
Jazyk:Anglicky/Francouzsky
Popis

IEC 60229:2007

Provides a range of tests which may be required for electric cables which have an extruded oversheath and where that oversheath performs a special protective function. The standard covers cables for use in insulated systems and in uninsulated systems. The tests are categorized for use as routine tests, type tests and tests after installation. These tests comprise of electrical routine tests on cable oversheath used in insulated or uninsulated systems, abrasion and corrosion spread type tests, electrical test on cable oversheath after installation. Routine tests and tests after installation, as specified in the relevant cable standards, are applicable for all situations. Type tests depend upon the nature of the system and the construction of the cable and do not have to be carried out for normal conditions of use. The significant technical changes with respect to the previous edition are as follows: - The text has been modified in order to consider the function of the oversheath, irrespective of the way the metallic sheath or screen of the cable is earthed because, in some cases, the oversheath is designed to act not only as a protection against corrosion, but also to reduce the risk of degradation of the cable insulation system. This requirement may be independent of the nature of the insulation and independent of the rated voltage of the cable. - More precise wording has been introduced regarding the application of some tests (if the sheaths or foils are bonded to the oversheath or not). - The test requirements have been revised in order to be in line with the standards published after the second edition. - The pressure test at high temperature has been deleted as the requirement is specified in the relevant cable standards. - A "Guidance on tests after installation" (Annex B) has been included.