Cena s DPH / bez DPH
Hlavní stránka>PD CEN/TR 13930:2009 Rotodynamic pumps. Design of pump intakes. Recommendations for installation of pumps
Sponsored link
sklademVydáno: 2010-08-31
PD CEN/TR 13930:2009 Rotodynamic pumps. Design of pump intakes. Recommendations for installation of pumps

PD CEN/TR 13930:2009

Rotodynamic pumps. Design of pump intakes. Recommendations for installation of pumps

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6448 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
644.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1934.40 Kč
Anglicky Tisk
Skladem
6448 Kč
Označení normy:PD CEN/TR 13930:2009
Počet stran:32
Vydáno:2010-08-31
ISBN:978 0 580 71461 0
Status:Standard
Popis

PD CEN/TR 13930:2009


This standard PD CEN/TR 13930:2009 Rotodynamic pumps. Design of pump intakes. Recommendations for installation of pumps is classified in these ICS categories:
  • 23.080 Pumps

1.1 This technical Report contains recommendations for the design of pump intakes and the installation of pumps.

As far as possible, these recommendations should be adhered to in order to obtain correct operation of the plant.

These recommendations are applicable regardless of the flow rate of the plant:

  • plant which works with clear water (or relatively unclouded) and relatively non-aerated water or any other liquid having physical and chemical properties which are similar to those of water;

NOTE This document nevertheless contains several general recommendations for operation with cloudy (or very cloudy) water.

  • pumping plant which has its own floor.

1.2 This document deals with various intake configurations:

  • Clause 3 contains recommendations which apply to intakes with vertical suction inlet;

  • Clause 4 contains recommendations applicable to intakes with top suction inlet;

  • Clause 5 contains recommendations applicable to intakes with floor suction inlet;

  • Clause 6 contains recommendations applicable to intakes with side-wall suction inlet.