Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>PD CEN/TR 16243:2011 Ambient air quality. Guide for the measurement of elemental carbon (EC) and organic carbon (OC) deposited on filters
Sponsored link
sklademVydáno: 2011-09-30
PD CEN/TR 16243:2011 Ambient air quality. Guide for the measurement of elemental carbon (EC) and organic carbon (OC) deposited on filters

PD CEN/TR 16243:2011

Ambient air quality. Guide for the measurement of elemental carbon (EC) and organic carbon (OC) deposited on filters

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
7998 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
799.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2399.40 Kč
Anglicky Tisk
Skladem
7998 Kč
Označení normy:PD CEN/TR 16243:2011
Počet stran:34
Vydáno:2011-09-30
ISBN:978 0 580 74012 1
Status:Standard
Popis

PD CEN/TR 16243:2011


This standard PD CEN/TR 16243:2011 Ambient air quality. Guide for the measurement of elemental carbon (EC) and organic carbon (OC) deposited on filters is classified in these ICS categories:
  • 13.040.20 Ambient atmospheres

This Technical Report gives guidance on the measurement of elemental carbon (EC) and organic carbon (OC) following the requirement for the networks of all EU member countries to measure EC and OC in particulate matter from June 2010 at background sites according to the Council Directive 2008/50/EC on ambient air quality and cleaner air for Europe.

The Technical Report describes the analytical procedures for determining EC and OC on quartz fibre filters as µg/cm2, and the subsequent calculation of concentrations as µg/m³. Sampling onto filters is to be done in accordance with EN 14907 for PM2,5. The sampling process determines the size fraction of the particulate matter, the retention of semi-volatile material, and ab/desorption of volatile organic compounds on the filter at the time of sampling.

The same analysis method may also be used for other size fractions. Any possible additional artefacts e.g. due to charring or higher concentrations of carbonates would need to be assessed in those cases.

The measurement procedures are applicable for:

  • rural background,

  • urban background,

  • road side and

  • industrial sites.

The scope includes non rural site measurements, to allow the assessment of additional exposure of people in urban areas as stated in the objectives of the council directive and to achieve coherence in the European approach. Measurements are made over a nominal sampling period of 24 h, and concentrations are expressed as µg/m³, where the volume of air is the volume at ambient conditions near the inlet of the sampler at the time of sampling.

The applicable concentration range of the proposed method is limited by the optical correction, instrument, and thermal protocols applied in the analysis of EC and OC. Therefore no definitive values can be given. The experience from EMEP shows the applicability of the method at regional background sites.