Cena s DPH / bez DPH
Hlavní stránka>PD CEN/TS 13649:2014 Stationary source emissions. Determination of the mass concentration of individual gaseous organic compounds. Sorptive sampling method followed by solvent extraction or thermal desorption
Sponsored link
sklademVydáno: 2014-12-31
PD CEN/TS 13649:2014 Stationary source emissions. Determination of the mass concentration of individual gaseous organic compounds. Sorptive sampling method followed by solvent extraction or thermal desorption

PD CEN/TS 13649:2014

Stationary source emissions. Determination of the mass concentration of individual gaseous organic compounds. Sorptive sampling method followed by solvent extraction or thermal desorption

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
8990 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
899.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2697.00 Kč
Anglicky Tisk
Skladem
8990 Kč
Označení normy:PD CEN/TS 13649:2014
Počet stran:52
Vydáno:2014-12-31
ISBN:978 0 580 74710 6
Status:Standard
Popis

PD CEN/TS 13649:2014


This standard PD CEN/TS 13649:2014 Stationary source emissions. Determination of the mass concentration of individual gaseous organic compounds. Sorptive sampling method followed by solvent extraction or thermal desorption is classified in these ICS categories:
  • 13.040.40 Stationary source emissions

This Technical Specification specifies procedures for the sampling, preparation and analysis of individual volatile organic compounds (VOCs) in waste gas, such as those arising from solvent using processes. Sampling occurs by adsorption on sorbents, preparation by solvent extraction or thermodesorption and analysis by gas chromatography.

Examples of individual VOC are given in relevant industry sector BAT Reference documents (BREFs).

The results obtained are expressed as the mass concentration (mg/m 3) of the individual gaseous organic compounds. This document is suitable for measuring individual VOCs whose ranges vary depending on compound and test method, refer to Annex B and C.

This Technical Specification may be used to meet the monitoring requirements of the Industrial Emission Directive (IED) and associated supporting documents.

This Technical Specification is not suitable for measuring total organic carbon (TOC). For the measurement of the mass concentration of total organic carbon then EN 12619 [3] is applicable.