Cena s DPH / bez DPH
Hlavní stránka>PD CEN/TS 17176-3:2022 Plastics piping systems for water supply and for buried and above ground drainage, sewerage and irrigation under pressure. Oriented unplasticized poly(vinyl chloride) (PVC-O) Fittings
Sponsored link
sklademVydáno: 2022-06-30
PD CEN/TS 17176-3:2022 Plastics piping systems for water supply and for buried and above ground drainage, sewerage and irrigation under pressure. Oriented unplasticized poly(vinyl chloride) (PVC-O) Fittings

PD CEN/TS 17176-3:2022

Plastics piping systems for water supply and for buried and above ground drainage, sewerage and irrigation under pressure. Oriented unplasticized poly(vinyl chloride) (PVC-O) Fittings

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6448 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
644.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1934.40 Kč
Anglicky Tisk
Skladem
6448 Kč
Označení normy:PD CEN/TS 17176-3:2022
Počet stran:28
Vydáno:2022-06-30
ISBN:978 0 539 18849 3
Status:Standard
Popis

PD CEN/TS 17176-3:2022


This standard PD CEN/TS 17176-3:2022 Plastics piping systems for water supply and for buried and above ground drainage, sewerage and irrigation under pressure. Oriented unplasticized poly(vinyl chloride) (PVC-O) is classified in these ICS categories:
  • 23.040.20 Plastics pipes
  • 23.040.45 Plastics fittings
This document specifies the characteristics of solid-wall oriented unplasticized poly(vinyl chloride) (PVC-O) fittings for piping systems intended for water supply and for buried drainage, sewerage, treated waste water and irrigation under pressure or above-ground where protected from direct sunlight. The scope of this document is limited to double sockets, repair couplings, reducers and to non-end load bearing elbows. NOTE 1 The scope of this document is restricted to fittings on the market during the preparation of this document. Therefore, tees, flange adaptors, etc., are excluded from this version of the standard. NOTE 2 For double sockets, repair couplings and reducers there are no special fittings designs for end-load bearing applications. However, restrained gaskets can be used for end-load bearing applications. In that case, the requirements of EN 17176-5 are applicable. It also specifies the test parameters for the test methods referred to in this document. In conjunction with EN 17176-1 and EN 17176-5, this document is applicable to oriented PVC-O fittings intended to be used for the following: a) water mains and services lines; b) conveyance of water for both outside and inside buildings; c) drainage, sewerage and treated waste water under pressure; d) irrigation under pressure. This document is applicable to piping systems intended for the supply of water with a maximum allowable operating pressure (PFA) up to and including 25 bar . The piping system according to this document is intended for the conveyance of cold water up to and including 45 °C and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations. For temperatures between 25 °C and 45 °C, EN 17176-2:2019, Figure C.1 applies. This document specifies a range of fittings sizes and pressure classes and gives a requirement and recommendations concerning colours. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.