Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>PD CEN/TS 18073:2024 Ambient air. Determination of lung deposited surface area (LDSA) concentration using aerosol monitors based on diffusion charging
Sponsored link
sklademVydáno: 2024-09-27
PD CEN/TS 18073:2024 Ambient air. Determination of lung deposited surface area (LDSA) concentration using aerosol monitors based on diffusion charging

PD CEN/TS 18073:2024

Ambient air. Determination of lung deposited surface area (LDSA) concentration using aerosol monitors based on diffusion charging

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
7998 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
799.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2399.40 Kč
Anglicky Tisk
Skladem
7998 Kč
Označení normy:PD CEN/TS 18073:2024
Počet stran:36
Vydáno:2024-09-27
ISBN:978 0 539 25287 3
Status:Standard
Popis

PD CEN/TS 18073:2024


This standard PD CEN/TS 18073:2024 Ambient air. Determination of lung deposited surface area (LDSA) concentration using aerosol monitors based on diffusion charging is classified in these ICS categories:
  • 13.040.20 Ambient atmospheres
This document specifies a process for the electrical diffusion charging of aerosols with subsequent measurement of particle charge. With the aid of this method, it is possible to determine the lung-deposited surface area (LDSA) concentration of particles in ambient air. Depending on the design of the electrical diffusion charger, the LDSA of particles in the size range of approximately 20 nm to approximately 300 nm is measurable. Furthermore, this document specifies design criteria for LDSA measuring aerosol monitors as well as performance criteria and the associated test procedures. The performance criteria depend on the application and they are more stringent when the instrument is operated in an air quality monitoring station. In the determination of the LDSA concentration, the share of geometric particle surface area concentration is determined that can be deposited in the alveolar region of the human lung. Typical particle surface area concentrations with alveolar deposition measured in urban areas range from 5 µm2/cm3 to 50 µm2/cm3. Instruments based on this measurement principle can be designed to be very compact with a low power consumption. This makes them ideally suited for handheld measurements, other forms of mobile application or to measure personal exposure. On the other hand, they can be easily adapted to serve as a stationary instrument in air quality monitoring stations.