Cena s DPH / bez DPH
Hlavní stránka>PD CISPR/TR 16-4-1:2009 Specification for radio disturbance and immunity measuring apparatus and methods Uncertainties, statistics and limit modelling. Uncertainties in standardized EMC tests
sklademVydáno: 2010-07-31
PD CISPR/TR 16-4-1:2009 Specification for radio disturbance and immunity measuring apparatus and methods Uncertainties, statistics and limit modelling. Uncertainties in standardized EMC tests

PD CISPR/TR 16-4-1:2009

Specification for radio disturbance and immunity measuring apparatus and methods Uncertainties, statistics and limit modelling. Uncertainties in standardized EMC tests

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9420 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
942.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2826.00 Kč
Anglicky Tisk
Skladem
9420 Kč
Označení normy:PD CISPR/TR 16-4-1:2009
Počet stran:122
Vydáno:2010-07-31
ISBN:978 0 580 61969 4
Status:Standard
Popis

PD CISPR/TR 16-4-1:2009


This standard PD CISPR/TR 16-4-1:2009 Specification for radio disturbance and immunity measuring apparatus and methods is classified in these ICS categories:
  • 33.100.20 Immunity
  • 33.100.10 Emission

This part of CISPR 16-4 gives guidance on the treatment of uncertainties to those who are involved in the development or modification of CISPR electromagnetic compatibility (EMC) standards. In addition, this part provides useful background information for those who apply the standards and the uncertainty aspects in practice.

The objectives of this part are to:

  1. identify the parameters or sources governing the uncertainty associated with the statement that a given product complies with the requirement specified in a CISPR recommendation. This uncertainty will be called “standards compliance uncertainty” (SCU, see 3.1.16);

  2. give guidance on the estimation of the magnitude of the standards compliance uncertainty;

  3. give guidance for the implementation of the standards compliance uncertainty into the compliance criterion of a CISPR standardised compliance test.

As such, this part can be considered as a handbook that can be used by standards writers to incorporate and harmonise uncertainty considerations in existing and future CISPR standards. This part also gives guidance to regulatory authorities, accreditation bodies and test engineers to judge the performance quality of an EMC test-laboratory carrying out CISPR standardised compliance tests. The uncertainty considerations given in this part can also be used as guidance when comparing test results (and their uncertainties) obtained by using different alternative test methods.

The uncertainty of a compliance test also relates to the probability of occurrence of an electromagnetic interference (EMI) problem in practice. This aspect is recognized and introduced briefly in this part. However, the problem of relating uncertainties of a compliance test to the occurrence of EMI in practice is not considered within the scope of this part.

The scope of this part is limited to all the relevant uncertainty considerations of a standardized EMC compliance test.