Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>PD IEC/TR 61243-6:2017 Live working. Voltage detectors Guidelines on non-contact voltage detectors (NCVD) for use at nominal voltages above 1 kV AC
Sponsored link
sklademVydáno: 2017-10-31
PD IEC/TR 61243-6:2017 Live working. Voltage detectors Guidelines on non-contact voltage detectors (NCVD) for use at nominal voltages above 1 kV AC

PD IEC/TR 61243-6:2017

Live working. Voltage detectors Guidelines on non-contact voltage detectors (NCVD) for use at nominal voltages above 1 kV AC

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
7998 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
799.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2399.40 Kč
Anglicky Tisk
Skladem
7998 Kč
Označení normy:PD IEC/TR 61243-6:2017
Počet stran:42
Vydáno:2017-10-31
ISBN:978 0 580 89676 7
Status:Standard
Popis

PD IEC/TR 61243-6:2017


This standard PD IEC/TR 61243-6:2017 Live working. Voltage detectors is classified in these ICS categories:
  • 29.240.99 Other equipment related to power transmission and distribution networks
  • 29.260.99 Other electrical equipment for working in special conditions
  • 29.240.20 Power transmission and distribution lines
  • 13.260 Protection against electric shock. Live working

This part of IEC 61243 , which is a Technical Report, is applicable to portable non-contact voltage detectors (NCVD) with built-in power source, to be used to indicate the presence or the absence of the operating voltage on electrical systems for nominal voltages above 1 kV AC and frequencies of 16 2/3 Hz, 50 Hz and/or 60 Hz.

NOTE

16,7 Hz is often referenced.

This document applies only to devices that are not designed to be used in contact with the bare part of the installation on which the presence or the absence of the operating voltage has to be tested.

This document describes only devices, and their behaviour, using electric field and voltage gradient detection principles even if other principles could be used. It provides performance guidelines, recommendations for use and recommended minimum criteria for selection.

Devices like personal safety distance voltage detectors, distance voltage detectors for emergency responders or machine operators are not covered by this document.

Except when otherwise specified, all the voltages defined in this document refer to phase-to-phase voltages of three-phase systems. In other systems, the applicable phase-to-phase or phase-to-earth (ground) voltages are used to determine the operating voltage.