Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>PD IEC/TR 62221:2012 Optical fibres. Measurement methods. Microbending sensitivity
Sponsored link
sklademVydáno: 2012-12-12
PD IEC/TR 62221:2012 Optical fibres. Measurement methods. Microbending sensitivity

PD IEC/TR 62221:2012

Optical fibres. Measurement methods. Microbending sensitivity

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6820 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
682.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2046.00 Kč
Anglicky Tisk
Skladem
6820 Kč
Označení normy:PD IEC/TR 62221:2012
Počet stran:28
Vydáno:2012-12-12
ISBN:978 0 580 77561 1
Status:Standard
Popis

PD IEC/TR 62221:2012


This standard PD IEC/TR 62221:2012 Optical fibres. Measurement methods. Microbending sensitivity is classified in these ICS categories:
  • 33.180.10 Fibres and cables

IEC 62221, which is a technical report , describes four methods (A, B, C and D) for the measurement of microbending sensitivity of optical fibres.

These four methods are distinguished by the equipment being used for measurements and their applications:

  • method A using an expandable drum and applies to category A1 and class B fibres;

  • method B using a fixed diameter drum and applies to category A1 and class B fibres;

  • method C using a plate and applied loads and applies to category A1 and class B fibres;

  • method D using a "basketweave" wrap on a fixed diameter drum, and applies to category A1 and class B fibres

Methods A and B may also be used to measure the microbending sensitivity of optical fibre ribbons.

Methods A and C offer the capability to measure the microbending sensitivity over a wide range of applied linear pressure or loads. Method B may be used to determine the microbending sensitivity for a fixed linear pressure.

Methods A, B and D can also be used at different temperatures (temperature cycling) provided special low thermal expansion materials (e.g. quartz drums) are used.

The results from the four methods can only be compared qualitatively . These methods are considered characterization type tests.

It shall be understood that the microbend results from any method, could have significant variation between laboratories .

These methods do not constitute a routine test used in the general evaluation of optical fibre. This parameter is not generally specified within a detail specification.