Cena s DPH / bez DPH
Hlavní stránka>PD IEC/TR 62630:2010 Guidance for evaluating exposure from multiple electromagnetic sources
Sponsored link
sklademVydáno: 2010-03-10
PD IEC/TR 62630:2010 Guidance for evaluating exposure from multiple electromagnetic sources

PD IEC/TR 62630:2010

Guidance for evaluating exposure from multiple electromagnetic sources

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
8556 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
855.60 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2566.80 Kč
Anglicky Tisk
Skladem
8556 Kč
Označení normy:PD IEC/TR 62630:2010
Počet stran:50
Vydáno:2010-03-10
ISBN:978 0 580 67860 8
Status:Standard
Popis

PD IEC/TR 62630:2010


This standard PD IEC/TR 62630:2010 Guidance for evaluating exposure from multiple electromagnetic sources is classified in these ICS categories:
  • 17.220.20 Measurement of electrical and magnetic quantities
  • 33.050.10 Telephone equipment

This Technical Report describes exposure evaluation concepts and techniques for the overall exposure level in spatial regions and occupants caused by the simultaneous exposure to multiple narrowband electromagnetic (EM) sources. Throughout this Technical Report, it is assumed that the exposure evaluation occurs under static conditions, i.e., the source position and transmit-mode characteristics (e.g. emitted power, modulation scheme, etc.) of the device(s) under test do not vary significantly over the time required to carry out the evaluation using the chosen evaluation technique (e.g., field measurements).

The vast majority of wireless communication systems worldwide employ signalling schemes featuring narrowband waveforms, hereinafter defined as signal waveforms occupying a frequency band not broader than 10 % of its central frequency (justification of this threshold is provided below). For information, Annex A presents the operating system bands and channel bandwidths of several common wireless services.

Wide-band communication systems, e.g., ultra-wideband (UWB) systems employing impulsive waveforms with fractional bandwidth well in excess of 10 %, are relatively new to the marketplace, have experienced limited deployment so far, and are not typically regarded as significant contributors to EM exposure levels due to low transmit power levels.

NOTE Present exposure evaluation standards for fixed or mobile wireless communication devices, e.g., IEC 62209-1, are mostly tailored towards defining suitable techniques for narrowband waveforms. For instance, they recommend the use of scalar E-field or H-field sensors, e.g., miniature diode-detector probes, which typically provide accurate readings for narrowband waveforms, as defined herein. The paucity of UWB wireless communication systems, which have only very recently been introduced in the marketplace, as well as the low power levels associated with the corresponding signals to avoid interfering with coexisting electronic systems, has so far reduced the priority to standardize suitable evaluation techniques and to develop the relevant test instrumentation.