Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>PD IEC TR 62669:2019 Case studies supporting IEC 62232. Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure
Sponsored link
sklademVydáno: 2019-06-14
PD IEC TR 62669:2019 Case studies supporting IEC 62232. Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure

PD IEC TR 62669:2019

Case studies supporting IEC 62232. Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
10230 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
1023.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
3069.00 Kč
Anglicky Tisk
Skladem
10230 Kč
Označení normy:PD IEC TR 62669:2019
Počet stran:128
Vydáno:2019-06-14
ISBN:978 0 580 52316 8
Status:Standard
Popis

PD IEC TR 62669:2019


This standard PD IEC TR 62669:2019 Case studies supporting IEC 62232. Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure is classified in these ICS categories:
  • 13.280 Radiation protection
  • 17.240 Radiation measurements

This document, which is a Technical Report, presents a series of case studies in which electromagnetic (EM) fields are evaluated in accordance with IEC 62232:2017. The case studies presented in this document involve intentionally radiating base stations (BS). The BS transmit on one or more antennas using one or more frequencies in the range 110 MHz to 100 GHz and RF exposure assessments take into account the contribution of ambient sources at least in the 100 kHz to 300 GHz frequency range.

Each case study has been chosen to illustrate a typical BS evaluation scenario and employs the methods detailed in IEC 62232:2017. The case studies are provided for guidance only and are not a substitute for a thorough understanding of the requirements of IEC 62232:2017. Based on the lessons learned from each case study, recommendations about RF assessment topics to be considered in the next revision of IEC 62232 are proposed. The methodologies and approaches described in this document are useful for the assessment of early 5G products introduced for consumer trials or deployments.

This document provides background and rationale for applying a compliance approach based on the actual maximum transmitted power or EIRP. Guidance for collecting and analysing information about the transmitted power of a base station and evaluating its actual maximum RF exposure based on modelling studies or measurement studies on operational sites (in networks, sub-networks or field trials) is also presented.